A preliminary study on the impact of environment to the heat of insulator

Ruihai Li, Kangtai Xu, Fuzeng Zhang, Zhuo Xu, Y. Tu, Bo Gong
{"title":"A preliminary study on the impact of environment to the heat of insulator","authors":"Ruihai Li, Kangtai Xu, Fuzeng Zhang, Zhuo Xu, Y. Tu, Bo Gong","doi":"10.1109/CEIDP.2013.6748271","DOIUrl":null,"url":null,"abstract":"Infrared temperature measurement technology is becoming increasingly applied in the detection of composite insulator defects. However, most evaluations of the operation condition of the insulators are based solely on the temperature rise without giving consideration to the factors of the environment, especially the temperature and humidity that the composite insulator is in. This paper focuses on the influence of temperature and humidity to temperature rise of the insulator and includes the study of a batch of overheating insulators from a transmission line. Differences are present in infrared temperature test results acquired from both the actual sites and in laboratories. Apart from this, the infrared test results change under various temperature and humidity in laboratory experiments. Therefore, taking consideration of the test environment is important in determining the degree of temperature rise. At last, suggestions on infrared detection are provided to guide testing at actual sites.","PeriodicalId":393969,"journal":{"name":"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2013.6748271","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Infrared temperature measurement technology is becoming increasingly applied in the detection of composite insulator defects. However, most evaluations of the operation condition of the insulators are based solely on the temperature rise without giving consideration to the factors of the environment, especially the temperature and humidity that the composite insulator is in. This paper focuses on the influence of temperature and humidity to temperature rise of the insulator and includes the study of a batch of overheating insulators from a transmission line. Differences are present in infrared temperature test results acquired from both the actual sites and in laboratories. Apart from this, the infrared test results change under various temperature and humidity in laboratory experiments. Therefore, taking consideration of the test environment is important in determining the degree of temperature rise. At last, suggestions on infrared detection are provided to guide testing at actual sites.
环境对绝缘子热影响的初步研究
红外测温技术在复合绝缘子缺陷检测中的应用越来越广泛。然而,大多数对绝缘子运行状态的评价仅仅基于温升,而没有考虑环境因素,特别是复合绝缘子所处的温度和湿度。本文主要研究了温度和湿度对绝缘子温升的影响,并对某输电线路的一批过热绝缘子进行了研究。从实际地点和实验室获得的红外温度测试结果存在差异。除此之外,在实验室实验中,红外测试结果在不同的温度和湿度下会发生变化。因此,在确定温升程度时,考虑测试环境是很重要的。最后对红外探测提出了建议,以指导实际现场的测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信