{"title":"Voltage Sag Assessment Considering Relay Protection Actions","authors":"Wenjie Fan, Xiangning Xiao, S. Tao","doi":"10.1109/PEAC.2018.8590316","DOIUrl":null,"url":null,"abstract":"The relay protection devices installed on the power grid lines will significantly change certain voltage sag indices. Taking this into account can improve the accuracy and credibility of the existing assessment methods. Based on the characteristics of relay protection configuration scheme, this paper analyzes the influence of stage distance protection and inverse time current protection action on voltage sag amplitude and duration, and derives the calculation formula of the sensible load failure rate. Based on IEEE 30-bus system, the voltage sag amplitude and duration are calculated by MATLAB program, whose results are then compared with the simulation results of PSCAD. The sensitivity load failure rate of a 66-bus isolated network, under the condition of with and without protection device operation, are evaluated and compared.","PeriodicalId":446770,"journal":{"name":"2018 IEEE International Power Electronics and Application Conference and Exposition (PEAC)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE International Power Electronics and Application Conference and Exposition (PEAC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEAC.2018.8590316","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The relay protection devices installed on the power grid lines will significantly change certain voltage sag indices. Taking this into account can improve the accuracy and credibility of the existing assessment methods. Based on the characteristics of relay protection configuration scheme, this paper analyzes the influence of stage distance protection and inverse time current protection action on voltage sag amplitude and duration, and derives the calculation formula of the sensible load failure rate. Based on IEEE 30-bus system, the voltage sag amplitude and duration are calculated by MATLAB program, whose results are then compared with the simulation results of PSCAD. The sensitivity load failure rate of a 66-bus isolated network, under the condition of with and without protection device operation, are evaluated and compared.
考虑继电保护动作的电压凹陷评估
继电保护装置安装在电网线路上,会显著改变某些电压凹陷指标。考虑到这一点可以提高现有评估方法的准确性和可信度。根据继电保护配置方案的特点,分析了级距保护和逆时电流保护动作对电压暂降幅度和持续时间的影响,推导出显载故障率的计算公式。基于IEEE 30总线系统,通过MATLAB程序计算电压骤降幅值和持续时间,并与PSCAD仿真结果进行比较。对66母线隔离网在带保护装置和不带保护装置工况下的敏感负载故障率进行了评估和比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信