Comparison reproducibility between the facebow and a new technique based on a spirit level device

Marina De Godoy Almeida, Mariângela Salles Pereira Nassar, C. Bataglion, F. V. de Mello Filho, Alexandre Laguna Terreri, C. Bataglion
{"title":"Comparison reproducibility between the facebow and a new technique based on a spirit level device","authors":"Marina De Godoy Almeida, Mariângela Salles Pereira Nassar, C. Bataglion, F. V. de Mello Filho, Alexandre Laguna Terreri, C. Bataglion","doi":"10.1080/08869634.2019.1650214","DOIUrl":null,"url":null,"abstract":"ABSTRACT Objective: This study aimed to introduce a spirit level device for mounting maxillary casts to compare the reproducibility between the facebow and this new technique. Methods: The maxillary casts of 10 participants were mounted in three different situations: 1) with the facebow; 2) with the spirit level device, the participant in seated position; and 3) with the spirit level device with participant in standing position. Each procedure was performed by three different evaluators. The values obtained were calculated using the Technical Error of Measurement (TEM) and the inter-evaluator Coefficient of Variation (CV). Results: The mean values obtained were 4.3 mm, 2.2 mm, and 2.6 mm for absolute TEM; 8.7%, 5.4%, and 6.4% for relative TEM; and 7.3%, 4.5%, and 5.6% for CV. Conclusion: These results show that the facebow is less reproducible compared to the new device, demonstrating that the new technique can be satisfactorily used in clinical practice.","PeriodicalId":162405,"journal":{"name":"CRANIO®","volume":"59 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"CRANIO®","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/08869634.2019.1650214","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

ABSTRACT Objective: This study aimed to introduce a spirit level device for mounting maxillary casts to compare the reproducibility between the facebow and this new technique. Methods: The maxillary casts of 10 participants were mounted in three different situations: 1) with the facebow; 2) with the spirit level device, the participant in seated position; and 3) with the spirit level device with participant in standing position. Each procedure was performed by three different evaluators. The values obtained were calculated using the Technical Error of Measurement (TEM) and the inter-evaluator Coefficient of Variation (CV). Results: The mean values obtained were 4.3 mm, 2.2 mm, and 2.6 mm for absolute TEM; 8.7%, 5.4%, and 6.4% for relative TEM; and 7.3%, 4.5%, and 5.6% for CV. Conclusion: These results show that the facebow is less reproducible compared to the new device, demonstrating that the new technique can be satisfactorily used in clinical practice.
脸弓与一种基于水平仪的新技术的可重复性比较
摘要目的:本研究旨在介绍一种用于上颌铸造固定的水平仪,比较脸弓与这种新技术的可重复性。方法:对10名上颌患者分别在三种不同的情况下进行上牙模的固定:1)面弓固定;2)配合水平仪,参与者处于坐位;3)与受试者站姿配合的水平仪。每个程序由三个不同的评估人员执行。采用技术测量误差(Technical Error of Measurement, TEM)和评价者间变异系数(interevaluator Coefficient of Variation, CV)计算所得值。结果:TEM绝对值平均值分别为4.3 mm、2.2 mm、2.6 mm;相对TEM为8.7%、5.4%、6.4%;CV分别为7.3%、4.5%和5.6%。结论:与新器械相比,脸弓的可重复性较低,表明新技术可令人满意地应用于临床。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信