{"title":"Performance Analysis of Different Tie-Line for Synchronization of 12-Area Two Interconnected Thermal Power Grid","authors":"P. Sahu","doi":"10.51983/ajes-2017.6.2.1997","DOIUrl":null,"url":null,"abstract":"This paper represents the advantages of HVAC-HVDC parallel tie-line as compare to the Flexible AC Transmission System (FACTS) tie-line and normal HVAC tie-line for synchronization of 12-area two interconnected thermal power grid with its all 12 areas when load changed in power grid-1 (area-6). After load change in power grid-1 (area-6), 12-area two interconnected thermal power grid with its all 12 areas are synchronized at the same time only in case of HVAC-HVDC parallel tie-line. This paper also shows the Flexible AC Transmission System (FACTS) tie-line is better as compare to the normal HVAC tie-line. Performance analysis of different tie-line for synchronization or load (machine) frequency control of 12-area two interconnected thermal power grid is done in terms of settling time of frequency deviation of all 12 areas and settling time of tie-line power deviation of two interconnected areas or two interconnected power grid by using conventional integral controller when load changed in power grid-1 (area-6).","PeriodicalId":365290,"journal":{"name":"Asian Journal of Electrical Sciences","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Electrical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51983/ajes-2017.6.2.1997","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper represents the advantages of HVAC-HVDC parallel tie-line as compare to the Flexible AC Transmission System (FACTS) tie-line and normal HVAC tie-line for synchronization of 12-area two interconnected thermal power grid with its all 12 areas when load changed in power grid-1 (area-6). After load change in power grid-1 (area-6), 12-area two interconnected thermal power grid with its all 12 areas are synchronized at the same time only in case of HVAC-HVDC parallel tie-line. This paper also shows the Flexible AC Transmission System (FACTS) tie-line is better as compare to the normal HVAC tie-line. Performance analysis of different tie-line for synchronization or load (machine) frequency control of 12-area two interconnected thermal power grid is done in terms of settling time of frequency deviation of all 12 areas and settling time of tie-line power deviation of two interconnected areas or two interconnected power grid by using conventional integral controller when load changed in power grid-1 (area-6).