{"title":"Average Household Grid Connected PV Generator with Different Intelligent Controllers","authors":"Sameh Mostafa, A. Zekry, A. Youssef, W. Anis","doi":"10.1109/NRSC52299.2021.9509783","DOIUrl":null,"url":null,"abstract":"This paper introduces a comparative analysis between three different controllers on a 9.2 kW grid-connected system. This system is designed using the Simulink to test the proposed controllers under the practical operating conditions for a household-sized photovoltaic system. The current study compares between three controllers (PI, Fuzzy and Fuzzy-PI) and attempts to choose the optimal controller for improving the performance of the grid-connected inverter control. The study concludes that the Fuzzy-PI controller outperforms the other ones regarding the performance parameters in terms of total harmonic distortion, dynamic response, settling time, and overshoot. This is attributed to the fact that the Fuzzy-PI changes the values of the gains (KI and KP) based on the variations in temperature and irradiance.","PeriodicalId":231431,"journal":{"name":"2021 38th National Radio Science Conference (NRSC)","volume":"104 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 38th National Radio Science Conference (NRSC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NRSC52299.2021.9509783","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
This paper introduces a comparative analysis between three different controllers on a 9.2 kW grid-connected system. This system is designed using the Simulink to test the proposed controllers under the practical operating conditions for a household-sized photovoltaic system. The current study compares between three controllers (PI, Fuzzy and Fuzzy-PI) and attempts to choose the optimal controller for improving the performance of the grid-connected inverter control. The study concludes that the Fuzzy-PI controller outperforms the other ones regarding the performance parameters in terms of total harmonic distortion, dynamic response, settling time, and overshoot. This is attributed to the fact that the Fuzzy-PI changes the values of the gains (KI and KP) based on the variations in temperature and irradiance.