[Electrocardiography in pediatrics. 1: Critical considerations of methods and experimental findings].

Padiatrie und Grenzgebiete Pub Date : 1992-01-01
H Schwartze, T Eifrig, K Ridwelski, E Maneck
{"title":"[Electrocardiography in pediatrics. 1: Critical considerations of methods and experimental findings].","authors":"H Schwartze,&nbsp;T Eifrig,&nbsp;K Ridwelski,&nbsp;E Maneck","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The results of experimental cardiology are reported on the basis of the electrophysiology of the heart. The QRS complex of the ECG, representing the spread of excitation through the ventricles, is used as an example to reflect the physiological and pathological events of the heart. The limitations of this example arise from the uncorrected recordings of the potential differences from the body surface. The need to use corrected lead systems is pointed out. The most commonly used FRANK lead system is extremely sensitive to the inaccurate positioning of lead points on the thorax. Evidence for this drawback is given by experimental findings in infantile and juvenile rats. It is clear that inaccurate positioning of electrodes is especially crucial in small subjects. A fundamental criticism of the FRANK lead system used in growing subjects is the impossibility of eliminating the errors caused by the changing geometry of the thorax of children of different ages. Improvement of the physical correction of ECG recordings in children for the purpose of reliable diagnostics is vital.</p>","PeriodicalId":19624,"journal":{"name":"Padiatrie und Grenzgebiete","volume":"31 1","pages":"27-41"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Padiatrie und Grenzgebiete","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The results of experimental cardiology are reported on the basis of the electrophysiology of the heart. The QRS complex of the ECG, representing the spread of excitation through the ventricles, is used as an example to reflect the physiological and pathological events of the heart. The limitations of this example arise from the uncorrected recordings of the potential differences from the body surface. The need to use corrected lead systems is pointed out. The most commonly used FRANK lead system is extremely sensitive to the inaccurate positioning of lead points on the thorax. Evidence for this drawback is given by experimental findings in infantile and juvenile rats. It is clear that inaccurate positioning of electrodes is especially crucial in small subjects. A fundamental criticism of the FRANK lead system used in growing subjects is the impossibility of eliminating the errors caused by the changing geometry of the thorax of children of different ages. Improvement of the physical correction of ECG recordings in children for the purpose of reliable diagnostics is vital.

儿科心电图学。[1]对方法和实验结果的关键考虑。
实验心脏病学的结果是在心脏电生理的基础上报告的。心电图的QRS复合体,代表兴奋通过心室的传播,作为一个例子来反映心脏的生理和病理事件。本例的局限性来自于体表电位差的未校正记录。指出了使用校正导联系统的必要性。最常用的FRANK导联系统对导联点在胸腔上的不准确定位极为敏感。在幼鼠和幼鼠身上的实验发现证明了这一缺陷。很明显,电极的不准确定位在小型实验对象中尤为重要。对用于成长对象的FRANK铅系统的一个基本批评是不可能消除由不同年龄儿童胸腔几何形状变化引起的误差。改善儿童心电图记录的物理校正以获得可靠的诊断是至关重要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信