More Efficient Solving Calibration Issues by Automated and Semi-Automated Calibration Systems

Tsung-Ping Lee
{"title":"More Efficient Solving Calibration Issues by Automated and Semi-Automated Calibration Systems","authors":"Tsung-Ping Lee","doi":"10.51843/wsproceedings.2018.41","DOIUrl":null,"url":null,"abstract":"From year 2015, owing to National Space Organization (here shorted by NSPO) internal a great quantity of requirements for instruments calibration, automated and semi-automated calibration systems started to build up, writing by computer programs C# to control and retrieve data from varies instruments and modules, in brand of instruments for example: Agilent, FLUKE, HP ,Keithley, Keysight, National Instruments and Tektronix. In order to solve issues of automatically generating uncertainties and calibration reports, templates using Microsoft Word according to the characteristics of the instrument have been classified and created. It benefits in calibration efficiency and precision because data retrieving and calibration reports can be created only one button. At the same time, calibration records can be found including uncertainty and degree of freedom of each component, expanded uncertainty and effective degree of freedom. After 2 years calibration experience, NSPO started to apply accreditation of Taiwan Accreditation Foundation (TAF) and have been accredited from April 10, 2017 by TAF. In order to satisfy requirements of TAF, for example: calibration report’s format, the logic of computer program by C# have been modified and validated by TAF. Therefore, NSPO can issue a report with both TAF logo and ILAC-MRA logo after calibrated instruments for customers. Owing to customers trust, NSPO stated to service external customers from May of 2017. Nowadays, NSPO have set up systems including Power Supply, Multi-Functions Meters, NI-4431 module series, Multi-functions Signal Generator, Current Probes, Electric-Load and Thermo-couple Meters. Systems in building and planning are Oscilloscope (building), Signal Conditioner (docs building) and Ionizing-gage/meters (planning, for High-Vacuum chambers). The main purpose to join this workshop is to share benefits of automated and semi-automated calibration system and to understand requirements from end-users.","PeriodicalId":120844,"journal":{"name":"NCSL International Workshop & Symposium Conference Proceedings 2018","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"NCSL International Workshop & Symposium Conference Proceedings 2018","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51843/wsproceedings.2018.41","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

From year 2015, owing to National Space Organization (here shorted by NSPO) internal a great quantity of requirements for instruments calibration, automated and semi-automated calibration systems started to build up, writing by computer programs C# to control and retrieve data from varies instruments and modules, in brand of instruments for example: Agilent, FLUKE, HP ,Keithley, Keysight, National Instruments and Tektronix. In order to solve issues of automatically generating uncertainties and calibration reports, templates using Microsoft Word according to the characteristics of the instrument have been classified and created. It benefits in calibration efficiency and precision because data retrieving and calibration reports can be created only one button. At the same time, calibration records can be found including uncertainty and degree of freedom of each component, expanded uncertainty and effective degree of freedom. After 2 years calibration experience, NSPO started to apply accreditation of Taiwan Accreditation Foundation (TAF) and have been accredited from April 10, 2017 by TAF. In order to satisfy requirements of TAF, for example: calibration report’s format, the logic of computer program by C# have been modified and validated by TAF. Therefore, NSPO can issue a report with both TAF logo and ILAC-MRA logo after calibrated instruments for customers. Owing to customers trust, NSPO stated to service external customers from May of 2017. Nowadays, NSPO have set up systems including Power Supply, Multi-Functions Meters, NI-4431 module series, Multi-functions Signal Generator, Current Probes, Electric-Load and Thermo-couple Meters. Systems in building and planning are Oscilloscope (building), Signal Conditioner (docs building) and Ionizing-gage/meters (planning, for High-Vacuum chambers). The main purpose to join this workshop is to share benefits of automated and semi-automated calibration system and to understand requirements from end-users.
通过自动化和半自动校准系统更有效地解决校准问题
从2015年开始,由于国家空间组织(以下简称NSPO)内部对仪器校准的大量需求,自动化和半自动校准系统开始建立,通过c#编写计算机程序来控制和检索各种仪器和模块的数据,例如:安捷伦,FLUKE,惠普,基斯利,是德科技,国家仪器和泰克等仪器品牌。为了解决自动生成不确定度和校准报告的问题,根据仪器的特点,利用Microsoft Word对模板进行了分类和创建。它有利于校准效率和精度,因为数据检索和校准报告可以只创建一个按钮。同时,可以找到标定记录,包括各部件的不确定度和自由度、扩展不确定度和有效自由度。经过2年的校准经验,NSPO开始申请台湾认可基金会(TAF)的认可,并于2017年4月10日获得TAF的认可。为了满足TAF的要求,例如:校准报告的格式,用c#对计算机程序的逻辑进行了修改,并通过TAF进行了验证。因此,NSPO可以在仪器校准后为客户出具同时带有TAF标志和ILAC-MRA标志的报告。由于客户的信任,NSPO表示从2017年5月开始服务外部客户。目前,NSPO已经建立了包括电源,多功能仪表,NI-4431模块系列,多功能信号发生器,电流探头,电负载和热电偶仪表等系统。在建设和规划系统是示波器(建设),信号调节器(文件建设)和电离计/米(规划,为高真空室)。参加本次研讨会的主要目的是分享自动化和半自动校准系统的好处,并了解最终用户的需求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信