J. Nedoma, M. Fajkus, R. Martínek, S. Kepak, J. Cubik, S. Zabka, V. Vasinek
{"title":"Comparison of BCG, PCG and ECG signals in application of heart rate monitoring of the human body","authors":"J. Nedoma, M. Fajkus, R. Martínek, S. Kepak, J. Cubik, S. Zabka, V. Vasinek","doi":"10.1109/TSP.2017.8076019","DOIUrl":null,"url":null,"abstract":"The aim of this article is evaluation and comparison of three different signals from three different sensors in application of monitoring the Heart Rate (HR) of the human body. Authors assembled two different types of fiber optic sensors. The first type of sensor uses Fiber Bragg Grating (FBG) and monitoring of heart rate is based on Ballistocardiography (BCG) principle. The second type of sensor utilizes fiber interferometer and monitoring of heart rate is based on Phonocardiography (PCG). Evaluation of signal from the first two types of sensors was acquired by proposed Optical Interrogators. In case of third type (reference signal), heart rate signal was acquired with the use of standard gel electrodes and modules fixed to the monitored person's chest using a real-time monitoring system for an Electrocardiography (ECG) with virtual instrumentation (National Instruments ELVIS II). The experimental tests were carried out on six subjects of both sexes in a laboratory conditions with their written consent. The obtained data were compared objectively by the Bland-Altman method.","PeriodicalId":256818,"journal":{"name":"2017 40th International Conference on Telecommunications and Signal Processing (TSP)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 40th International Conference on Telecommunications and Signal Processing (TSP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TSP.2017.8076019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16
Abstract
The aim of this article is evaluation and comparison of three different signals from three different sensors in application of monitoring the Heart Rate (HR) of the human body. Authors assembled two different types of fiber optic sensors. The first type of sensor uses Fiber Bragg Grating (FBG) and monitoring of heart rate is based on Ballistocardiography (BCG) principle. The second type of sensor utilizes fiber interferometer and monitoring of heart rate is based on Phonocardiography (PCG). Evaluation of signal from the first two types of sensors was acquired by proposed Optical Interrogators. In case of third type (reference signal), heart rate signal was acquired with the use of standard gel electrodes and modules fixed to the monitored person's chest using a real-time monitoring system for an Electrocardiography (ECG) with virtual instrumentation (National Instruments ELVIS II). The experimental tests were carried out on six subjects of both sexes in a laboratory conditions with their written consent. The obtained data were compared objectively by the Bland-Altman method.
本文的目的是评估和比较来自三种不同传感器的三种不同信号在监测人体心率(HR)中的应用。作者组装了两种不同类型的光纤传感器。第一种传感器采用光纤布拉格光栅(FBG),监测心率是基于ballisocardiography (BCG)原理。第二类传感器采用光纤干涉仪,以心音图(PCG)为基础监测心率。对来自前两种传感器的信号进行评估是由所提出的光学询问器获得的。在第三种情况下(参考信号),使用标准凝胶电极和固定在被监测人胸部的模块获取心率信号,使用虚拟仪器(National Instruments ELVIS II)的实时心电图监测系统(ECG)。实验测试在实验室条件下对六名男女受试者进行,并得到他们的书面同意。采用Bland-Altman方法对所得数据进行客观比较。