Stability assessment using synchrophasor data

Pratim Kundu, A. Pradhan
{"title":"Stability assessment using synchrophasor data","authors":"Pratim Kundu, A. Pradhan","doi":"10.1109/ICEAS.2011.6147077","DOIUrl":null,"url":null,"abstract":"Rotor angle variation during post fault period in a power system leads to power swing. Both stable and unstable swings may cause tripping of distance relays and therefore they are blocked during swinging conditions. The unstable swing if not detected early or dealt properly leads to loss of synchronism among different areas and consequently resulting in catastrophic failures such as blackouts. To avoid such incidents some of the relays placed at strategic locations have to be unblocked. An integrated approach of combining various indices derived from wide area measurement system (WAMS) data using fuzzy logic for ranking the severity of the swing has been proposed. The ranking aids in taking decisions regarding the blocking and unblocking of relays to avoid severe failures. The performances of the indices have been tested on a three-machine nine-bus system using EMTDC/PSCAD and MATLAB.","PeriodicalId":273164,"journal":{"name":"2011 International Conference on Energy, Automation and Signal","volume":"62 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Energy, Automation and Signal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEAS.2011.6147077","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Rotor angle variation during post fault period in a power system leads to power swing. Both stable and unstable swings may cause tripping of distance relays and therefore they are blocked during swinging conditions. The unstable swing if not detected early or dealt properly leads to loss of synchronism among different areas and consequently resulting in catastrophic failures such as blackouts. To avoid such incidents some of the relays placed at strategic locations have to be unblocked. An integrated approach of combining various indices derived from wide area measurement system (WAMS) data using fuzzy logic for ranking the severity of the swing has been proposed. The ranking aids in taking decisions regarding the blocking and unblocking of relays to avoid severe failures. The performances of the indices have been tested on a three-machine nine-bus system using EMTDC/PSCAD and MATLAB.
利用同步相量数据进行稳定性评估
电力系统故障后转子角度的变化会引起功率的摆动。稳定和不稳定的摆动都可能导致距离继电器跳闸,因此在摆动期间继电器被阻塞。不稳定的摆动如果不及早发现或处理不当,将导致不同区域之间失去同步,从而导致停电等灾难性故障。为避免此类事件,必须疏通位于战略地点的一些继电器。提出了一种利用模糊逻辑对广域测量系统(WAMS)数据的各种指标进行综合评价的方法。排名有助于对继电器的阻塞和解除阻塞作出决定,以避免严重的故障。利用EMTDC/PSCAD和MATLAB在三机九总线系统上对指标的性能进行了测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信