Assessment of 3D Scanners for Modeling Pectus Carinatum Corrective Bar

António H. J. Moreira, João Gomes Fonseca, P. Rodrigues, J. Fonseca, A. Pinho, J. Correia-Pinto, N. Rodrigues, J. Vilaça
{"title":"Assessment of 3D Scanners for Modeling Pectus Carinatum Corrective Bar","authors":"António H. J. Moreira, João Gomes Fonseca, P. Rodrigues, J. Fonseca, A. Pinho, J. Correia-Pinto, N. Rodrigues, J. Vilaça","doi":"10.5220/0004300901220125","DOIUrl":null,"url":null,"abstract":"Pectus Carinatum (PC) is a chest deformity consisting on the anterior protrusion of the sternum and adjacent costal cartilages. Non-operative corrections, such as the orthotic compression brace, require previous information of the patient chest surface, to improve the overall brace fit. This paper focuses on the validation of the Kinect scanner for the modelling of an orthotic compression brace for the correction of Pectus Carinatum. To this extent, a phantom chest wall surface was acquired using two scanner systems – Kinect and Polhemus FastSCAN – and compared through CT. The results show a RMS error of 3.25mm between the CT data and the surface mesh from the Kinect sensor and 1.5mm from the FastSCAN sensor.","PeriodicalId":411140,"journal":{"name":"International Conference on Computer Vision Theory and Applications","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-08-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Computer Vision Theory and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5220/0004300901220125","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Pectus Carinatum (PC) is a chest deformity consisting on the anterior protrusion of the sternum and adjacent costal cartilages. Non-operative corrections, such as the orthotic compression brace, require previous information of the patient chest surface, to improve the overall brace fit. This paper focuses on the validation of the Kinect scanner for the modelling of an orthotic compression brace for the correction of Pectus Carinatum. To this extent, a phantom chest wall surface was acquired using two scanner systems – Kinect and Polhemus FastSCAN – and compared through CT. The results show a RMS error of 3.25mm between the CT data and the surface mesh from the Kinect sensor and 1.5mm from the FastSCAN sensor.
胸凸矫正棒三维扫描仪建模的评估
胸突(PC)是一种胸部畸形,由胸骨前突和邻近的肋软骨组成。非手术矫正,如矫形压缩支具,需要患者以前的胸部表面信息,以提高整体支具配合度。本文的重点是验证Kinect扫描仪对矫正胸大肌的矫形压缩支架的建模。在这种程度上,使用两种扫描系统(Kinect和Polhemus FastSCAN)获取幻像胸壁表面,并通过CT进行比较。结果表明,Kinect传感器的CT数据与表面网格的均方根误差为3.25mm, FastSCAN传感器的均方根误差为1.5mm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信