Glasses for the Third Eye: Improving the Quality of Clinical Data Analysis with Motion Sensor-based Data Filtering

Jaeyeon Park, Woojin Nam, Jaewon Choi, Taeyeong Kim, D. Yoon, Sukhoon Lee, Jeongyeup Paek, Jeonggil Ko
{"title":"Glasses for the Third Eye: Improving the Quality of Clinical Data Analysis with Motion Sensor-based Data Filtering","authors":"Jaeyeon Park, Woojin Nam, Jaewon Choi, Taeyeong Kim, D. Yoon, Sukhoon Lee, Jeongyeup Paek, Jeonggil Ko","doi":"10.1145/3131672.3131690","DOIUrl":null,"url":null,"abstract":"Recent advances in machine learning based data analytics are opening opportunities for designing effective clinical decision support systems (CDSS) which can become the \"third-eye\" in the current clinical procedures and diagnosis. However, common patient movements in hospital wards may lead to faulty measurements in physiological sensor readings, and training a CDSS from such noisy data can cause misleading predictions, directly leading to potentially dangerous clinical decisions. In this work, we present MediSense, a system to sense, classify, and identify noise-causing motions and activities that affect physiological signal when made by patients on their hospital beds. Essentially, such a system can be considered as \"glasses\" for the clinical third eye in correctly observing medical data. MediSense combines wirelessly connected embedded platforms for motion detection with physiological signal data collected from patients to identify faulty physiological signal measurements and filters such noisy data from being used in CDSS training or testing datasets. We deploy our system in real intensive care units (ICUs), and evaluate its performance from real patient traces collected at these ICUs through a 4-month pilot study at the Ajou University Hospital Trauma Center, a major hospital facility located in Suwon, South Korea. Our results show that MediSense successfully classifies patient motions on the bed with >90% accuracy, shows 100% reliability in determining the locations of beds within the ICU, and each bed-attached sensor achieves a lifetime of more than 33 days, which satisfies the application-level requirements suggested by our clinical partners. Furthermore, a simple case-study with arrhythmia patient data shows that MediSense can help improve the clinical diagnosis accuracy.","PeriodicalId":424262,"journal":{"name":"Proceedings of the 15th ACM Conference on Embedded Network Sensor Systems","volume":"21 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 15th ACM Conference on Embedded Network Sensor Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3131672.3131690","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20

Abstract

Recent advances in machine learning based data analytics are opening opportunities for designing effective clinical decision support systems (CDSS) which can become the "third-eye" in the current clinical procedures and diagnosis. However, common patient movements in hospital wards may lead to faulty measurements in physiological sensor readings, and training a CDSS from such noisy data can cause misleading predictions, directly leading to potentially dangerous clinical decisions. In this work, we present MediSense, a system to sense, classify, and identify noise-causing motions and activities that affect physiological signal when made by patients on their hospital beds. Essentially, such a system can be considered as "glasses" for the clinical third eye in correctly observing medical data. MediSense combines wirelessly connected embedded platforms for motion detection with physiological signal data collected from patients to identify faulty physiological signal measurements and filters such noisy data from being used in CDSS training or testing datasets. We deploy our system in real intensive care units (ICUs), and evaluate its performance from real patient traces collected at these ICUs through a 4-month pilot study at the Ajou University Hospital Trauma Center, a major hospital facility located in Suwon, South Korea. Our results show that MediSense successfully classifies patient motions on the bed with >90% accuracy, shows 100% reliability in determining the locations of beds within the ICU, and each bed-attached sensor achieves a lifetime of more than 33 days, which satisfies the application-level requirements suggested by our clinical partners. Furthermore, a simple case-study with arrhythmia patient data shows that MediSense can help improve the clinical diagnosis accuracy.
第三眼眼镜:用基于运动传感器的数据过滤提高临床数据分析的质量
基于机器学习的数据分析的最新进展为设计有效的临床决策支持系统(CDSS)提供了机会,这些系统可以成为当前临床程序和诊断中的“第三只眼睛”。然而,医院病房中常见的病人运动可能导致生理传感器读数测量错误,并且从这种嘈杂的数据中训练CDSS可能导致误导性预测,直接导致潜在危险的临床决策。在这项工作中,我们提出了MediSense,这是一个系统,用于感知、分类和识别患者在病床上产生的影响生理信号的噪声运动和活动。从本质上讲,这样的系统可以被认为是临床第三只眼睛正确观察医疗数据的“眼镜”。MediSense将用于运动检测的无线连接嵌入式平台与从患者身上收集的生理信号数据相结合,以识别错误的生理信号测量,并过滤用于CDSS训练或测试数据集的此类噪声数据。我们在真正的重症监护病房(icu)中部署了我们的系统,并通过在位于韩国水原的一家主要医院——亚洲大学医院创伤中心进行的为期4个月的试点研究,从这些icu收集的真实患者痕迹中评估其性能。我们的研究结果表明,MediSense成功地对患者在床上的运动进行分类,准确率>90%,在确定ICU内床位位置方面显示出100%的可靠性,每个床上传感器的使用寿命超过33天,满足我们临床合作伙伴提出的应用级要求。此外,一个简单的心律失常患者数据案例研究表明,MediSense有助于提高临床诊断的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书