Surface Characterization on Electrophoretic Deposition Oof 316l Stainless Steel with Dissolved Chitosan for Biomedical Application

P. Setyarini, F. Gapsari, Apollo Ode Rea Harjo
{"title":"Surface Characterization on Electrophoretic Deposition Oof 316l Stainless Steel with Dissolved Chitosan for Biomedical Application","authors":"P. Setyarini, F. Gapsari, Apollo Ode Rea Harjo","doi":"10.21776/mechta.2022.003.01.6","DOIUrl":null,"url":null,"abstract":"Of many compounds materials, metallic biomaterial is widely used in human medical devices. An implant material's corrosion resistance impacts its flexibility and longevity. This corrosion resistance is also an important consideration for biocompatibility. This biomaterial contains stainless steel whcih may corrode after being installed in the human body since  the passivity of stainless steel disappears when it is exposed to acids in the human body for a long duration. In addition, lacks of oxygen inhibits the formation of a new Cr2O3 layer for corrosion protection. Based on this phenomenon, an advance treatment is required to improve the resistance corrosion of implant. This study investigates the effect of the concentration and duration of chitosan on the thickness and corrosion resistance of biomaterials. The concentration of chitosan used was 0.08%, 0.16%, and 0.24% while the voltage used was constant at 10 V. The test results demonstrated the lowest corrosion rate occrured for 0.24 % chitosan concentration with 30 minutes coating duration. The lowest corrosion rate achieved was 0.014 mmpy and the maximum thickness was 75.4 μm. This study could be then used as a new solution to increase the safety of existing implants using biodegradable and non-toxic compounds. The next experiment should be implantation in real human body.","PeriodicalId":159477,"journal":{"name":"International Journal of Mechanical Engineering Technologies and Applications","volume":"72 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Mechanical Engineering Technologies and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21776/mechta.2022.003.01.6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Of many compounds materials, metallic biomaterial is widely used in human medical devices. An implant material's corrosion resistance impacts its flexibility and longevity. This corrosion resistance is also an important consideration for biocompatibility. This biomaterial contains stainless steel whcih may corrode after being installed in the human body since  the passivity of stainless steel disappears when it is exposed to acids in the human body for a long duration. In addition, lacks of oxygen inhibits the formation of a new Cr2O3 layer for corrosion protection. Based on this phenomenon, an advance treatment is required to improve the resistance corrosion of implant. This study investigates the effect of the concentration and duration of chitosan on the thickness and corrosion resistance of biomaterials. The concentration of chitosan used was 0.08%, 0.16%, and 0.24% while the voltage used was constant at 10 V. The test results demonstrated the lowest corrosion rate occrured for 0.24 % chitosan concentration with 30 minutes coating duration. The lowest corrosion rate achieved was 0.014 mmpy and the maximum thickness was 75.4 μm. This study could be then used as a new solution to increase the safety of existing implants using biodegradable and non-toxic compounds. The next experiment should be implantation in real human body.
生物医学用溶解壳聚糖电泳沉积316l不锈钢的表面表征
在众多化合物材料中,金属生物材料被广泛应用于人体医疗器械。植入材料的耐腐蚀性影响其柔韧性和使用寿命。这种耐腐蚀性也是生物相容性的重要考虑因素。这种生物材料含有不锈钢,在人体中安装后可能会被腐蚀,因为不锈钢长时间接触人体中的酸就会失去活性。此外,缺氧抑制了新的Cr2O3层的形成。基于这种现象,需要对种植体进行提前处理,以提高种植体的抗腐蚀能力。研究了壳聚糖浓度和时间对生物材料厚度和耐蚀性的影响。壳聚糖的浓度分别为0.08%、0.16%和0.24%,电压恒定为10 V。实验结果表明,壳聚糖浓度为0.24%,涂层时间为30 min时,腐蚀速率最低。腐蚀速率最小为0.014 mmpy,腐蚀厚度最大为75.4 μm。这项研究可以作为一种新的解决方案,使用可生物降解和无毒的化合物来提高现有植入物的安全性。下一步的实验应该是在真正的人体植入。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信