Primary Standard of Attenuation in the Frequency Range of 1 kHz to 10 MHz

A. Widarta
{"title":"Primary Standard of Attenuation in the Frequency Range of 1 kHz to 10 MHz","authors":"A. Widarta","doi":"10.1109/CPEM49742.2020.9191824","DOIUrl":null,"url":null,"abstract":"Primary standard of attenuation in the frequency range of 1 kHz to 10 MHz is developed to meet the demands in recent EMC regulations that require traceability of measurements to national standards. A null detection system with an IVD as a reference standard is constructed to allow attenuation at 1 kHz, 9 kHz, and 10 kHz to be measured accurately by comparing to the voltage ratio of the IVD. Attenuation in the frequency range of 100 kHz to 10 MHz is measured in the same procedure after being down converted to 1 kHz using heterodyne detection technique. A double step technique is introduced in measurements at 9 kHz and 10kHz to keep high accuracy results due to increasing of the IVD uncertainties. Higher dynamic range is obtained by installing toroidal ferrite chokes in the system to minimize common-mode leakages in the kilohertz frequency range. The measurement capability is expected to be larger than 60 dB with the expanded uncertainty range starting from 0.0016 dB.","PeriodicalId":373216,"journal":{"name":"2020 Conference on Precision Electromagnetic Measurements (CPEM)","volume":"182 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 Conference on Precision Electromagnetic Measurements (CPEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM49742.2020.9191824","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Primary standard of attenuation in the frequency range of 1 kHz to 10 MHz is developed to meet the demands in recent EMC regulations that require traceability of measurements to national standards. A null detection system with an IVD as a reference standard is constructed to allow attenuation at 1 kHz, 9 kHz, and 10 kHz to be measured accurately by comparing to the voltage ratio of the IVD. Attenuation in the frequency range of 100 kHz to 10 MHz is measured in the same procedure after being down converted to 1 kHz using heterodyne detection technique. A double step technique is introduced in measurements at 9 kHz and 10kHz to keep high accuracy results due to increasing of the IVD uncertainties. Higher dynamic range is obtained by installing toroidal ferrite chokes in the system to minimize common-mode leakages in the kilohertz frequency range. The measurement capability is expected to be larger than 60 dB with the expanded uncertainty range starting from 0.0016 dB.
1千赫至10兆赫频率范围内衰减的主要标准
开发了1 kHz至10 MHz频率范围内衰减的主要标准,以满足最近EMC法规的要求,这些法规要求测量可追溯到国家标准。构建了一个以IVD为参考标准的零检测系统,通过比较IVD的电压比,可以精确测量1 kHz、9 kHz和10 kHz的衰减。使用外差检测技术将衰减转换为1 kHz后,在相同的程序中测量100 kHz至10 MHz频率范围内的衰减。由于IVD不确定度的增加,在9khz和10kHz的测量中引入了双步进技术,以保持较高的测量精度。通过在系统中安装环形铁氧体扼流圈来减少千赫兹频率范围内的共模泄漏,可以获得更高的动态范围。测量能力预计大于60 dB,扩展的不确定度范围从0.0016 dB开始。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信