ATP analysis of direct lightning strike on a telecommunication tower suited over multistoriec building

Md. Zoyheroul Islam, Md. Salah Uddin Yusuf
{"title":"ATP analysis of direct lightning strike on a telecommunication tower suited over multistoriec building","authors":"Md. Zoyheroul Islam, Md. Salah Uddin Yusuf","doi":"10.1109/ECACE.2017.7912935","DOIUrl":null,"url":null,"abstract":"Now a days lightning performance of telecommunication tower is an important issue of major interest for wireless communication service provider utility companies. Lightning is the most important and severe external transient phenomenon that can cause dangerous over voltages on transmission line, damages of sophisticated electronic equipment, terrible induced high voltages as well as electromagnetic compatibility problems on power transmission and telecommunication system. Telecommunication tower suited on the roof of multistoried building can be easily hit by direct lightning strike and telecommunication tower can cause dangerous overvoltages, which can result in malfunction of the sensitive equipment as well as dangerous step and touch voltages then finally hampered the communication system connected to the tower. This paper demonstrates the lightning surge response and effect of direct stroke for typical mobile phone tower suited on multistoried building roof. The simulation of the electromagnetic transient process, caused from the lightning stroke on the different portion of the tower and building have been carried out over the usage of the ATP Draw (Alternative Transient Program) software tool. ATP Draw is a mouse-driven, graphical preprocessor to the ATP version of the Electromagnetic Transients Program (EMTP) on the Microsoft Windows platform. The Alternative Transients Program (ATP) is considered to be one of the most widely used universal program in electric power systems for digital simulation of transient phenomena of electromagnetic as well as electromechanical nature. The key focus of the study has been the assessment of the surge characteristics of the different portion of the structure under the effect of a lightning sources. Surge impedance, Voltage and currents at different portion of this tower are evaluated to observe lightning phenomena for designing of protective equipment to save the sensitive electronic parts and equipment contains tower and building.","PeriodicalId":333370,"journal":{"name":"2017 International Conference on Electrical, Computer and Communication Engineering (ECCE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Electrical, Computer and Communication Engineering (ECCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECACE.2017.7912935","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Now a days lightning performance of telecommunication tower is an important issue of major interest for wireless communication service provider utility companies. Lightning is the most important and severe external transient phenomenon that can cause dangerous over voltages on transmission line, damages of sophisticated electronic equipment, terrible induced high voltages as well as electromagnetic compatibility problems on power transmission and telecommunication system. Telecommunication tower suited on the roof of multistoried building can be easily hit by direct lightning strike and telecommunication tower can cause dangerous overvoltages, which can result in malfunction of the sensitive equipment as well as dangerous step and touch voltages then finally hampered the communication system connected to the tower. This paper demonstrates the lightning surge response and effect of direct stroke for typical mobile phone tower suited on multistoried building roof. The simulation of the electromagnetic transient process, caused from the lightning stroke on the different portion of the tower and building have been carried out over the usage of the ATP Draw (Alternative Transient Program) software tool. ATP Draw is a mouse-driven, graphical preprocessor to the ATP version of the Electromagnetic Transients Program (EMTP) on the Microsoft Windows platform. The Alternative Transients Program (ATP) is considered to be one of the most widely used universal program in electric power systems for digital simulation of transient phenomena of electromagnetic as well as electromechanical nature. The key focus of the study has been the assessment of the surge characteristics of the different portion of the structure under the effect of a lightning sources. Surge impedance, Voltage and currents at different portion of this tower are evaluated to observe lightning phenomena for designing of protective equipment to save the sensitive electronic parts and equipment contains tower and building.
适用于多层建筑的电信塔的直接雷击的ATP分析
目前,电信铁塔的雷电性能是无线通信服务提供商和公用事业公司关心的一个重要问题。雷电是一种重要而严重的外部暂态现象,它会对输电线路造成危险的过电压,损坏精密电子设备,产生可怕的感应高压,并对输电和电信系统造成电磁兼容问题。适用于多层建筑屋顶的电信塔容易受到直击雷击,电信塔会产生危险的过电压,从而导致敏感设备的故障,并产生危险的步进电压和接触电压,最终使与塔相连的通信系统陷入瘫痪。本文对适用于多层建筑屋顶的典型移动电话塔的雷击浪涌响应及直接冲击效应进行了分析。利用ATP Draw (Alternative transient Program)软件工具,对雷击对塔和建筑物不同部位产生的电磁瞬变过程进行了模拟。ATP Draw是一个鼠标驱动的图形预处理器,用于Microsoft Windows平台上的电磁瞬变程序(EMTP)的ATP版本。备选暂态程序(ATP)被认为是电力系统中应用最广泛的用于电磁和机电性质暂态现象数字仿真的通用程序之一。研究的重点是评估雷源作用下结构不同部分的浪涌特性。通过对该塔不同部位的浪涌阻抗、电压和电流进行评估,观察雷电现象,为设计保护设备提供依据,以保护敏感的电子部件和包含塔和建筑物的设备。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信