Cecily J. Gallup, S. E. Cabreriza, J. Hart, R. Walsh, A. Weinberg, H. M. Spotnitz
{"title":"Left ventricular end-diastolic volume from ejection fraction and stroke volume in pigs during IVC occlusion.","authors":"Cecily J. Gallup, S. E. Cabreriza, J. Hart, R. Walsh, A. Weinberg, H. M. Spotnitz","doi":"10.1006/JSRE.2002.6432","DOIUrl":null,"url":null,"abstract":"BACKGROUND\nReal-time measurement of left ventricular end-diastolic volume (LVEDV), combined with left ventricular end-diastolic pressure (LVEDP), would allow continuous measurement of intraoperative diastolic function. In pursuit of this goal, we examined stroke volume divided by ejection fraction for calculation of LVEDV(sv/ef).\n\n\nMETHODS\nFive anesthetized pigs underwent median sternotomy and pericardiotomy. A transit-time ultrasonic flow probe on the ascending aorta provided cardiac output. A micromanometer provided LV end-diastolic pressure. End-diastolic and end-systolic areas were measured from LV short-axis cross sections to obtain ejection fraction. LVEDV(sv/ef) was calculated during IVC occlusion. Steady-state LVEDV(echo) was determined using a three-plane echocardiography model. LVEDV(echo) was used to validate steady-state LVEDA in each experiment.\n\n\nRESULTS\nCorrelation coefficients for linear and pressure-volume relation analyses ranged from 0.46 to 0.99. The two methods for measuring LVEDV generated compliance curves with an overall reliability coefficient of 0.84.\n\n\nCONCLUSIONS\nThe LVEDV(sv/ef) method may facilitate real-time determination of LV compliance.","PeriodicalId":191568,"journal":{"name":"The Journal of surgical research","volume":"538 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of surgical research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1006/JSRE.2002.6432","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
BACKGROUND
Real-time measurement of left ventricular end-diastolic volume (LVEDV), combined with left ventricular end-diastolic pressure (LVEDP), would allow continuous measurement of intraoperative diastolic function. In pursuit of this goal, we examined stroke volume divided by ejection fraction for calculation of LVEDV(sv/ef).
METHODS
Five anesthetized pigs underwent median sternotomy and pericardiotomy. A transit-time ultrasonic flow probe on the ascending aorta provided cardiac output. A micromanometer provided LV end-diastolic pressure. End-diastolic and end-systolic areas were measured from LV short-axis cross sections to obtain ejection fraction. LVEDV(sv/ef) was calculated during IVC occlusion. Steady-state LVEDV(echo) was determined using a three-plane echocardiography model. LVEDV(echo) was used to validate steady-state LVEDA in each experiment.
RESULTS
Correlation coefficients for linear and pressure-volume relation analyses ranged from 0.46 to 0.99. The two methods for measuring LVEDV generated compliance curves with an overall reliability coefficient of 0.84.
CONCLUSIONS
The LVEDV(sv/ef) method may facilitate real-time determination of LV compliance.