{"title":"Performance of a Semi-Closed Oxy-Fuel Combustion Combined Cycle (SCOC-CC) With an Air Separation Unit (ASU)","authors":"Majed Sammak, Marcus Thern, Magnus Genrup","doi":"10.1115/GT2018-76218","DOIUrl":null,"url":null,"abstract":"The objective of this paper is to evaluate the performance of a semi-closed oxy-fuel combustion combined cycle (SCOC-CC) and its power penalties. The power penalties are associated with CO2 compression and high-pressure oxygen production in the air separation unit (ASU). The paper discusses three different methods for high pressure oxygen (O2) production. Method 1 is producing O2 directly at high pressure by compressing the air before the air separation takes place. Method 2 is producing O2 at low pressure and then compressing the separated O2 to the desired pressure with a compressor. Method 3 is alike the second method, except that the separated liquid O2 is pressurized with a liquid oxygen pump to the desired pressure.\n The studied SCOC-CC is a dual-pressure level steam cycle due to its comparable efficiency with three pressure level steam cycle and less complexity.\n The SCOC-CC, ASU and CO2 compression train are modeled with the commercial heat and mass balance software IPSEpro. The paper analyzed the SCOC-CC performance at different combustion outlet temperatures and pressure ratios. The combustion outlet temperature (COT) varied from 1200 °C to 1550 °C and the pressure ratio varied from 25 to 45.\n The study is concerned with mid-sized SCOC-CC with a net power output 100 MW. The calculations were performed at the selected design point which was at 1400°C and pressure ratio at 37. The calculated power consumption of the O2 separation at a purity of 95 % was 719 kJ/kgO2. The power consumption for pressurizing the separated O2 (method 2) was 345 kJ/kgO2 whereas it was 4.4 kJ/kgO2 for pumping liquid O2 to the required pressure (method 3). The calculated power consumption for pressurizing and pumping the CO2-enriched stream was 323 kJ/kgCO2.\n The SCOC-CC gross efficiency was 57.6 %. The SCOC-CC net efficiency at method 2 for air separation was 46.7 %. The gross efficiency was reduced by 9 % due to ASU and other 2 % due to CO2 compression. The SCOC-CC net efficiency at method 3 of the air separation was 49.6 %. The ASU reduced the gross efficiency by 6 % and additional 2 % by CO2 compression. Using method 3 for air separation gave a 3 % gain in cycle efficiency.","PeriodicalId":131179,"journal":{"name":"Volume 3: Coal, Biomass, and Alternative Fuels; Cycle Innovations; Electric Power; Industrial and Cogeneration; Organic Rankine Cycle Power Systems","volume":"65 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 3: Coal, Biomass, and Alternative Fuels; Cycle Innovations; Electric Power; Industrial and Cogeneration; Organic Rankine Cycle Power Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/GT2018-76218","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
The objective of this paper is to evaluate the performance of a semi-closed oxy-fuel combustion combined cycle (SCOC-CC) and its power penalties. The power penalties are associated with CO2 compression and high-pressure oxygen production in the air separation unit (ASU). The paper discusses three different methods for high pressure oxygen (O2) production. Method 1 is producing O2 directly at high pressure by compressing the air before the air separation takes place. Method 2 is producing O2 at low pressure and then compressing the separated O2 to the desired pressure with a compressor. Method 3 is alike the second method, except that the separated liquid O2 is pressurized with a liquid oxygen pump to the desired pressure.
The studied SCOC-CC is a dual-pressure level steam cycle due to its comparable efficiency with three pressure level steam cycle and less complexity.
The SCOC-CC, ASU and CO2 compression train are modeled with the commercial heat and mass balance software IPSEpro. The paper analyzed the SCOC-CC performance at different combustion outlet temperatures and pressure ratios. The combustion outlet temperature (COT) varied from 1200 °C to 1550 °C and the pressure ratio varied from 25 to 45.
The study is concerned with mid-sized SCOC-CC with a net power output 100 MW. The calculations were performed at the selected design point which was at 1400°C and pressure ratio at 37. The calculated power consumption of the O2 separation at a purity of 95 % was 719 kJ/kgO2. The power consumption for pressurizing the separated O2 (method 2) was 345 kJ/kgO2 whereas it was 4.4 kJ/kgO2 for pumping liquid O2 to the required pressure (method 3). The calculated power consumption for pressurizing and pumping the CO2-enriched stream was 323 kJ/kgCO2.
The SCOC-CC gross efficiency was 57.6 %. The SCOC-CC net efficiency at method 2 for air separation was 46.7 %. The gross efficiency was reduced by 9 % due to ASU and other 2 % due to CO2 compression. The SCOC-CC net efficiency at method 3 of the air separation was 49.6 %. The ASU reduced the gross efficiency by 6 % and additional 2 % by CO2 compression. Using method 3 for air separation gave a 3 % gain in cycle efficiency.