Performance of a Semi-Closed Oxy-Fuel Combustion Combined Cycle (SCOC-CC) With an Air Separation Unit (ASU)

Majed Sammak, Marcus Thern, Magnus Genrup
{"title":"Performance of a Semi-Closed Oxy-Fuel Combustion Combined Cycle (SCOC-CC) With an Air Separation Unit (ASU)","authors":"Majed Sammak, Marcus Thern, Magnus Genrup","doi":"10.1115/GT2018-76218","DOIUrl":null,"url":null,"abstract":"The objective of this paper is to evaluate the performance of a semi-closed oxy-fuel combustion combined cycle (SCOC-CC) and its power penalties. The power penalties are associated with CO2 compression and high-pressure oxygen production in the air separation unit (ASU). The paper discusses three different methods for high pressure oxygen (O2) production. Method 1 is producing O2 directly at high pressure by compressing the air before the air separation takes place. Method 2 is producing O2 at low pressure and then compressing the separated O2 to the desired pressure with a compressor. Method 3 is alike the second method, except that the separated liquid O2 is pressurized with a liquid oxygen pump to the desired pressure.\n The studied SCOC-CC is a dual-pressure level steam cycle due to its comparable efficiency with three pressure level steam cycle and less complexity.\n The SCOC-CC, ASU and CO2 compression train are modeled with the commercial heat and mass balance software IPSEpro. The paper analyzed the SCOC-CC performance at different combustion outlet temperatures and pressure ratios. The combustion outlet temperature (COT) varied from 1200 °C to 1550 °C and the pressure ratio varied from 25 to 45.\n The study is concerned with mid-sized SCOC-CC with a net power output 100 MW. The calculations were performed at the selected design point which was at 1400°C and pressure ratio at 37. The calculated power consumption of the O2 separation at a purity of 95 % was 719 kJ/kgO2. The power consumption for pressurizing the separated O2 (method 2) was 345 kJ/kgO2 whereas it was 4.4 kJ/kgO2 for pumping liquid O2 to the required pressure (method 3). The calculated power consumption for pressurizing and pumping the CO2-enriched stream was 323 kJ/kgCO2.\n The SCOC-CC gross efficiency was 57.6 %. The SCOC-CC net efficiency at method 2 for air separation was 46.7 %. The gross efficiency was reduced by 9 % due to ASU and other 2 % due to CO2 compression. The SCOC-CC net efficiency at method 3 of the air separation was 49.6 %. The ASU reduced the gross efficiency by 6 % and additional 2 % by CO2 compression. Using method 3 for air separation gave a 3 % gain in cycle efficiency.","PeriodicalId":131179,"journal":{"name":"Volume 3: Coal, Biomass, and Alternative Fuels; Cycle Innovations; Electric Power; Industrial and Cogeneration; Organic Rankine Cycle Power Systems","volume":"65 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 3: Coal, Biomass, and Alternative Fuels; Cycle Innovations; Electric Power; Industrial and Cogeneration; Organic Rankine Cycle Power Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/GT2018-76218","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The objective of this paper is to evaluate the performance of a semi-closed oxy-fuel combustion combined cycle (SCOC-CC) and its power penalties. The power penalties are associated with CO2 compression and high-pressure oxygen production in the air separation unit (ASU). The paper discusses three different methods for high pressure oxygen (O2) production. Method 1 is producing O2 directly at high pressure by compressing the air before the air separation takes place. Method 2 is producing O2 at low pressure and then compressing the separated O2 to the desired pressure with a compressor. Method 3 is alike the second method, except that the separated liquid O2 is pressurized with a liquid oxygen pump to the desired pressure. The studied SCOC-CC is a dual-pressure level steam cycle due to its comparable efficiency with three pressure level steam cycle and less complexity. The SCOC-CC, ASU and CO2 compression train are modeled with the commercial heat and mass balance software IPSEpro. The paper analyzed the SCOC-CC performance at different combustion outlet temperatures and pressure ratios. The combustion outlet temperature (COT) varied from 1200 °C to 1550 °C and the pressure ratio varied from 25 to 45. The study is concerned with mid-sized SCOC-CC with a net power output 100 MW. The calculations were performed at the selected design point which was at 1400°C and pressure ratio at 37. The calculated power consumption of the O2 separation at a purity of 95 % was 719 kJ/kgO2. The power consumption for pressurizing the separated O2 (method 2) was 345 kJ/kgO2 whereas it was 4.4 kJ/kgO2 for pumping liquid O2 to the required pressure (method 3). The calculated power consumption for pressurizing and pumping the CO2-enriched stream was 323 kJ/kgCO2. The SCOC-CC gross efficiency was 57.6 %. The SCOC-CC net efficiency at method 2 for air separation was 46.7 %. The gross efficiency was reduced by 9 % due to ASU and other 2 % due to CO2 compression. The SCOC-CC net efficiency at method 3 of the air separation was 49.6 %. The ASU reduced the gross efficiency by 6 % and additional 2 % by CO2 compression. Using method 3 for air separation gave a 3 % gain in cycle efficiency.
带空气分离装置(ASU)的半封闭氧-燃料燃烧联合循环(SCOC-CC)性能研究
本文的目的是评估半封闭氧燃料燃烧联合循环(SCOC-CC)的性能及其功率损失。功率损失与空气分离装置(ASU)中的二氧化碳压缩和高压氧气生产有关。本文讨论了三种不同的高压制氧方法。方法一是在空气分离前通过压缩空气直接在高压下生产氧气。方法二是在低压下产生氧气,然后用压缩机将分离出来的氧气压缩到所需的压力。方法3与第二种方法相似,只是用液氧泵将分离的液态O2加压到所需的压力。所研究的SCOC-CC是双压力级蒸汽循环,其效率与三压力级蒸汽循环相当,且复杂性较低。SCOC-CC, ASU和CO2压缩列车用商业热质量平衡软件IPSEpro建模。本文分析了不同出口温度和压力比下SCOC-CC的性能。燃烧出口温度(COT)在1200 ~ 1550℃之间变化,压力比在25 ~ 45之间变化。该研究涉及中型SCOC-CC,净功率输出为100兆瓦。计算在选定的设计点1400°C和压力比37进行。在纯度为95%时,O2分离的计算功耗为719 kJ/kgO2。方法2加压分离O2的功率消耗为345 kJ/kgO2,而将液态O2泵送至所需压力的功率消耗为4.4 kJ/kgO2(方法3)。计算出加压和泵送co2富集流的功率消耗为323 kJ/kgCO2。SCOC-CC总效率为57.6%。空气分离方法2的SCOC-CC净效率为46.7%。总效率由于ASU降低了9%,由于CO2压缩降低了2%。空气分离方法3下,SCOC-CC净效率为49.6%。ASU将总效率降低了6%,二氧化碳压缩又降低了2%。采用方法3进行空分,循环效率提高3%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信