Lateral shearing interferometry with continuously variable shear ratio

Zhi-Yu Cai, Junyong Zhang, Pengqian Yang
{"title":"Lateral shearing interferometry with continuously variable shear ratio","authors":"Zhi-Yu Cai, Junyong Zhang, Pengqian Yang","doi":"10.1117/12.2617726","DOIUrl":null,"url":null,"abstract":"Lateral shearing interferometry with different shear ratio has different measurement sensitivity, which corresponds to different measurement accuracy. To image the wavefront of an unknown system, high precision measurement accuracy is particularly important. Here a quadriwave lateral shearing interferometry (QWLSI) with continuous adjustable shear ratio is proposed, in which the light splitting grating is placed in the front of the first condenser lens rather than in late position for the traditional QWLSI. In this case, the shear ratio is proportional to the ratio of the defocusing amount to the focal length of the imaging lens. The newly developed QWLSI with continuously variable shear ratio, not only can measure the system aberration, but also calibrate the spatial resolution of the measured wavefront. Software GLAD simulation and experimental results on phase imaging show that the proposed scheme can not only realize variable-shear-ratio interferogram but also has a good robustness, which is well suitable for quantitative phase imaging.","PeriodicalId":198425,"journal":{"name":"Other Conferences","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Other Conferences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2617726","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Lateral shearing interferometry with different shear ratio has different measurement sensitivity, which corresponds to different measurement accuracy. To image the wavefront of an unknown system, high precision measurement accuracy is particularly important. Here a quadriwave lateral shearing interferometry (QWLSI) with continuous adjustable shear ratio is proposed, in which the light splitting grating is placed in the front of the first condenser lens rather than in late position for the traditional QWLSI. In this case, the shear ratio is proportional to the ratio of the defocusing amount to the focal length of the imaging lens. The newly developed QWLSI with continuously variable shear ratio, not only can measure the system aberration, but also calibrate the spatial resolution of the measured wavefront. Software GLAD simulation and experimental results on phase imaging show that the proposed scheme can not only realize variable-shear-ratio interferogram but also has a good robustness, which is well suitable for quantitative phase imaging.
连续变剪切比横向剪切干涉测量
不同剪切比的横向剪切干涉测量具有不同的测量灵敏度,对应不同的测量精度。要对未知系统的波前进行成像,高精度的测量精度尤为重要。本文提出了一种剪切比连续可调的四波横向剪切干涉法(QWLSI),该方法将分光光栅置于第一聚光镜的前部,而不是传统的四波横向剪切干涉法的后部位置。在这种情况下,剪切比与离焦量与成像透镜焦距的比例成正比。新开发的连续变剪切比QWLSI不仅可以测量系统像差,还可以校准被测波前的空间分辨率。软件GLAD仿真和相位成像实验结果表明,该方案不仅可以实现变剪切比干涉图,而且具有良好的鲁棒性,非常适合于定量相位成像。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信