Sensor-on-CMOS dielectric characterization using temperature modulation

Jun-Chau Chien, A. Niknejad
{"title":"Sensor-on-CMOS dielectric characterization using temperature modulation","authors":"Jun-Chau Chien, A. Niknejad","doi":"10.1109/ARFTG.2015.7381458","DOIUrl":null,"url":null,"abstract":"In this paper, on-chip temperature modulation is applied in a CMOS-based dielectric sensor for the determination of sample temperature coefficients in a microfluidic setting. System uncertainties are taken into account by a multi-step calibration with the use of on-chip metal-based switched-capacitors. Using de-ionized water as reference, the temperature coefficients of saline and methanol-water mixture are extracted at 17.5 GHz with temperature spanning from 32 ~ 37 °C.","PeriodicalId":170825,"journal":{"name":"2015 86th ARFTG Microwave Measurement Conference","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 86th ARFTG Microwave Measurement Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ARFTG.2015.7381458","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In this paper, on-chip temperature modulation is applied in a CMOS-based dielectric sensor for the determination of sample temperature coefficients in a microfluidic setting. System uncertainties are taken into account by a multi-step calibration with the use of on-chip metal-based switched-capacitors. Using de-ionized water as reference, the temperature coefficients of saline and methanol-water mixture are extracted at 17.5 GHz with temperature spanning from 32 ~ 37 °C.
使用温度调制的cmos传感器介电特性
本文将片上温度调制应用于基于cmos的介质传感器中,用于微流体环境中样品温度系数的测定。采用片上金属基开关电容器进行多步校准,考虑了系统的不确定性。以去离子水为参比,在17.5 GHz频率下提取生理盐水和甲醇-水混合物的温度系数,温度范围为32 ~ 37℃。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信