{"title":"Practical Experience Of PMU Data Quality Monitoring In Control Rooms","authors":"A. V. Zhukov, N. A. Karimov, D. Dubinin","doi":"10.1109/RPA57581.2022.9951094","DOIUrl":null,"url":null,"abstract":"The active development of the transient monitoring system in power system of Russia and the technical characteristics of the information and communication infrastructure of the System operator make it possible to use phasor measurement unit (PMU) to solve practical problems of operational dispatch control [1]. At the moment, technological software that performs the functions of informing dispatch personnel in real time based on PMU data has been implemented in control rooms. The functioning of data collection systems depends on the quality of the incoming data. Decreased data quality can lead to software failure and issuance of outdated or false information to dispatch personnel. «System Operator of the United Power System» (SO UPS) put into operation the technological software of PMU data quality monitoring.The article explores the issues of data quality deterioration, as well as the problems that affect their occurrence. This article gives an analysis of the international experience of organization of data quality monitoring and formation of methodology and approaches to the analysis and description of parameters characterizing data quality. It is spoken in detail the software operating in SO UPS, designed for continuous monitoring of the quality of PMU data and allowing offline analysis of quality indicators and the dynamics of their change. The text gives a valuable information about experience of the first real application of the continuous monitoring system PMU data quality is presented and analyzed.","PeriodicalId":413852,"journal":{"name":"2022 5th International Youth Scientific and Technical Conference on Relay Protection and Automation (RPA)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 5th International Youth Scientific and Technical Conference on Relay Protection and Automation (RPA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RPA57581.2022.9951094","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The active development of the transient monitoring system in power system of Russia and the technical characteristics of the information and communication infrastructure of the System operator make it possible to use phasor measurement unit (PMU) to solve practical problems of operational dispatch control [1]. At the moment, technological software that performs the functions of informing dispatch personnel in real time based on PMU data has been implemented in control rooms. The functioning of data collection systems depends on the quality of the incoming data. Decreased data quality can lead to software failure and issuance of outdated or false information to dispatch personnel. «System Operator of the United Power System» (SO UPS) put into operation the technological software of PMU data quality monitoring.The article explores the issues of data quality deterioration, as well as the problems that affect their occurrence. This article gives an analysis of the international experience of organization of data quality monitoring and formation of methodology and approaches to the analysis and description of parameters characterizing data quality. It is spoken in detail the software operating in SO UPS, designed for continuous monitoring of the quality of PMU data and allowing offline analysis of quality indicators and the dynamics of their change. The text gives a valuable information about experience of the first real application of the continuous monitoring system PMU data quality is presented and analyzed.