{"title":"An Adaptive Control Strategy for Dynamic Response of an Autonomous DC system","authors":"F. Norouzi, L. Elizondo, T. Hoppe, P. Bauer","doi":"10.1109/UPEC50034.2021.9548156","DOIUrl":null,"url":null,"abstract":"The dynamic behaviour - steady-state and transient - of the DC Microgrids during power disturbance can affect the system’s general performance. A hybrid combination of energy storage devices with slow frequency response, like a Fuel Cell, and with a fast dynamic response, like a Super-Capacitor, provides an improved dynamic response to stabilise DC bus voltage. However, control parameters should be designed based on the preferences of the system. This paper proposes a fuzzy-based controller to determine the Virtual Capacitor Droop controller to achieve the desired transient response. The proposed dynamic control method is validated through MATLAB/Simulink.","PeriodicalId":325389,"journal":{"name":"2021 56th International Universities Power Engineering Conference (UPEC)","volume":"268 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 56th International Universities Power Engineering Conference (UPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC50034.2021.9548156","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The dynamic behaviour - steady-state and transient - of the DC Microgrids during power disturbance can affect the system’s general performance. A hybrid combination of energy storage devices with slow frequency response, like a Fuel Cell, and with a fast dynamic response, like a Super-Capacitor, provides an improved dynamic response to stabilise DC bus voltage. However, control parameters should be designed based on the preferences of the system. This paper proposes a fuzzy-based controller to determine the Virtual Capacitor Droop controller to achieve the desired transient response. The proposed dynamic control method is validated through MATLAB/Simulink.
自主直流系统动态响应的自适应控制策略
直流微电网在电力干扰下的动态特性(稳态和暂态)会影响系统的总体性能。频率响应慢的储能设备(如燃料电池)和快速动态响应的储能设备(如超级电容器)的混合组合,提供了改进的动态响应,以稳定直流母线电压。然而,控制参数的设计应基于系统的偏好。本文提出了一种基于模糊的控制器来确定虚拟电容下垂控制器以达到所需的暂态响应。通过MATLAB/Simulink对所提出的动态控制方法进行了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信