Building Equivalent Static Earthquake Loading Based on RSA Soil Data and Sondir

Paikun Paikun, Dede Fauzi Fitrullatif, Dicki Gustaman, M. Hidayat, Nauval Aziz, Marwahyudi Marwahyudi
{"title":"Building Equivalent Static Earthquake Loading Based on RSA Soil Data and Sondir","authors":"Paikun Paikun, Dede Fauzi Fitrullatif, Dicki Gustaman, M. Hidayat, Nauval Aziz, Marwahyudi Marwahyudi","doi":"10.1109/icced56140.2022.10010463","DOIUrl":null,"url":null,"abstract":"Calculation of earthquake loads so far using soil data input from sonder test results refers to the provisions of SNI 1726:2002, while in the current digital era there is a soil detection-based application, namely Response Spectrum Application (RSA) or Indonesian Spectrum Design referring to the provisions of SNI 1726:2019. Based on the differences in the data sources, it is necessary to know whether the results of the earthquake load analysis will be the same or different. This study aims to compare the planning analysis of earthquake loads in high-rise buildings with specifications for reinforced concrete structures using the Equivalent Static Analysis method. Soil data used is the response spectrum data from sonder test results, and the website Indonesian Spectra Response Design or RSA. The results of the analysis show that the earthquake load will be greater on the higher floors. Earthquake load based on analysis of ground sonder data was 23.38% higher on average compared to the results of RSA data analysis. The difference in earthquake loads will affect the difference in the dimensions of the structure, therefore the dimensions of the earthquake-resistant building structure based on the analysis of the soil sonder will be larger, so the building that has been standing since 2002 can be declared safe. Analysis of earthquake loads based on RSA data is easier and more practical, but the results are not yet able to determine the dimensions of the foundation and the depth of the foundation.","PeriodicalId":200030,"journal":{"name":"2022 IEEE 8th International Conference on Computing, Engineering and Design (ICCED)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 8th International Conference on Computing, Engineering and Design (ICCED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/icced56140.2022.10010463","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Calculation of earthquake loads so far using soil data input from sonder test results refers to the provisions of SNI 1726:2002, while in the current digital era there is a soil detection-based application, namely Response Spectrum Application (RSA) or Indonesian Spectrum Design referring to the provisions of SNI 1726:2019. Based on the differences in the data sources, it is necessary to know whether the results of the earthquake load analysis will be the same or different. This study aims to compare the planning analysis of earthquake loads in high-rise buildings with specifications for reinforced concrete structures using the Equivalent Static Analysis method. Soil data used is the response spectrum data from sonder test results, and the website Indonesian Spectra Response Design or RSA. The results of the analysis show that the earthquake load will be greater on the higher floors. Earthquake load based on analysis of ground sonder data was 23.38% higher on average compared to the results of RSA data analysis. The difference in earthquake loads will affect the difference in the dimensions of the structure, therefore the dimensions of the earthquake-resistant building structure based on the analysis of the soil sonder will be larger, so the building that has been standing since 2002 can be declared safe. Analysis of earthquake loads based on RSA data is easier and more practical, but the results are not yet able to determine the dimensions of the foundation and the depth of the foundation.
基于RSA土数据和Sondir的建筑等效静力地震荷载
迄今为止,利用探测仪测试结果输入的土壤数据计算地震荷载参照SNI 1726:2002的规定,而在当前的数字时代,有一种基于土壤检测的应用,即响应谱应用(RSA)或印尼谱设计,参照SNI 1726:2019的规定。基于数据源的差异,需要知道地震荷载分析的结果是否相同或不同。本研究将采用等效静力分析方法对高层建筑地震荷载规划分析与钢筋混凝土结构规范进行比较。使用的土壤数据是来自超声波测试结果的响应谱数据,以及印度尼西亚光谱响应设计(RSA)网站。分析结果表明,楼层越高,地震荷载越大。基于地面测深数据分析的地震荷载比RSA数据分析结果平均高23.38%。地震荷载的差异会影响结构尺寸的差异,因此基于土测仪分析的抗震建筑结构尺寸会更大,因此自2002年以来一直屹立的建筑物可以宣布安全。基于RSA数据的地震荷载分析更容易,更实用,但结果尚不能确定基础的尺寸和基础的深度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信