{"title":"Investigation on parallel operation of two MMC-HVDC links in grid forming connected to an existing network","authors":"H. Saad, P. Rault, S. Dennetière","doi":"10.23919/EPE20ECCEEurope43536.2020.9215741","DOIUrl":null,"url":null,"abstract":"The share of power electronics installations into existing ac power systems is significantly increasing due to the massive penetration of wind power plants and HVDC links. VSC-HVDC link can operate in VF -control (or grid-forming mode) when connected to a weak or islanded network to overcome the PQ-control (or grid-feeding mode) limitation. Up to now, the VF -control represents a challenge due to static and dynamic limits when several HVDC links are in parallel operation. This paper provides a dynamic performance of two HVDC links in grid forming mode connected to an islanded grid. To provide a realistic test case, the islanded grid is based on the Northern France network. AC fault and control instabilities between 2 HVDC links in VF control are analyzed in this work. These set of EMT studies provide an insight on dynamic network behavior when HVDC is operating in VF control.","PeriodicalId":241752,"journal":{"name":"2020 22nd European Conference on Power Electronics and Applications (EPE'20 ECCE Europe)","volume":"93 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 22nd European Conference on Power Electronics and Applications (EPE'20 ECCE Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/EPE20ECCEEurope43536.2020.9215741","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
The share of power electronics installations into existing ac power systems is significantly increasing due to the massive penetration of wind power plants and HVDC links. VSC-HVDC link can operate in VF -control (or grid-forming mode) when connected to a weak or islanded network to overcome the PQ-control (or grid-feeding mode) limitation. Up to now, the VF -control represents a challenge due to static and dynamic limits when several HVDC links are in parallel operation. This paper provides a dynamic performance of two HVDC links in grid forming mode connected to an islanded grid. To provide a realistic test case, the islanded grid is based on the Northern France network. AC fault and control instabilities between 2 HVDC links in VF control are analyzed in this work. These set of EMT studies provide an insight on dynamic network behavior when HVDC is operating in VF control.