LQR Control of Input LC filter of a Tram with On-board Energy Storage System

J. Talla, L. Streit, Š. Janouš, Ondrej Suchý
{"title":"LQR Control of Input LC filter of a Tram with On-board Energy Storage System","authors":"J. Talla, L. Streit, Š. Janouš, Ondrej Suchý","doi":"10.1109/AE54730.2022.9920058","DOIUrl":null,"url":null,"abstract":"The main traction power converter of a trams is connected to DC trolley wire by input LC filter. The tram input LC filter is almost undamped resonant circuit, which is often loaded by the motor constant torque command. Sources of the input LC filter oscillation may be present on the vehicle, typically drive control influence. The source of LC filter excitation except the tram drive could be the tram’s trolley voltage caused by fluctuations in power consumption and harmonics from surrounding vehicles, and temporary loss of catenary voltage caused by crossings of insulated sections or icing on catenary. The next source could be the tram ESS, which is connected in parallel to the tram dc-link capacitor. The dynamic ESS control, which is necessary for majority of power management techniques, can also destabilize the LC filter. On the other hand, the proper ESS control could be used for LC-filter stabilization. The LQR based stabilization of LC filter using ESS is presented in this paper.","PeriodicalId":113076,"journal":{"name":"2022 International Conference on Applied Electronics (AE)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Conference on Applied Electronics (AE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AE54730.2022.9920058","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The main traction power converter of a trams is connected to DC trolley wire by input LC filter. The tram input LC filter is almost undamped resonant circuit, which is often loaded by the motor constant torque command. Sources of the input LC filter oscillation may be present on the vehicle, typically drive control influence. The source of LC filter excitation except the tram drive could be the tram’s trolley voltage caused by fluctuations in power consumption and harmonics from surrounding vehicles, and temporary loss of catenary voltage caused by crossings of insulated sections or icing on catenary. The next source could be the tram ESS, which is connected in parallel to the tram dc-link capacitor. The dynamic ESS control, which is necessary for majority of power management techniques, can also destabilize the LC filter. On the other hand, the proper ESS control could be used for LC-filter stabilization. The LQR based stabilization of LC filter using ESS is presented in this paper.
车载储能有轨电车输入LC滤波器的LQR控制
有轨电车主牵引电源变换器通过输入LC滤波器与直流电车导线连接。有轨电车输入LC滤波器几乎是无阻尼谐振电路,通常由电机恒转矩指令加载。输入LC滤波器振荡的来源可能存在于车辆上,通常是驱动控制的影响。除有轨电车驱动外,LC滤波器励磁的来源可能是由于用电波动和周围车辆的谐波引起的有轨电车的电车电压,以及由于绝缘路段交叉或接触网结冰引起的接触网电压的暂时损失。下一个电源可能是有轨电车ESS,它与有轨电车直流电容并联。动态ESS控制是大多数电源管理技术所必需的,也会使LC滤波器不稳定。另一方面,适当的ESS控制可以用于lc滤波器的稳定。提出了一种基于LQR的基于ESS的LC滤波器稳定化方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信