Seismic response of the long-span steel truss arch bridge with the thrust under multidimensional excitation

Yongliang Zhang, Jibei Ma, Xingchong Chen, Yun Wang
{"title":"Seismic response of the long-span steel truss arch bridge with the thrust under multidimensional excitation","authors":"Yongliang Zhang, Jibei Ma, Xingchong Chen, Yun Wang","doi":"10.1108/rs-04-2022-0005","DOIUrl":null,"url":null,"abstract":"PurposeUnder different ground motion excitation modes, the spatial coupling effect of seismic response for the arch bridge with thrust, seismic weak parts and the internal force components of the control section of main arch ribs are analyzed.Design/methodology/approachTaking a 490 m deck type railway steel truss arch bridge as the background, the dynamic calculation model of the whole bridge was established by SAP2000 software. The seismic response analyses under one-, two- and three-dimension (1D, 2D and 3D) uniform ground motion excitations were carried out.FindingsFor the steel truss arch bridge composed of multiple arch ribs, any single direction ground motion excitation will cause large axial force in the chord of arch rib. The axial force caused by transverse and vertical ground motion excitation in the chord of arch crown area is 1.4–3.6 times of the corresponding axial force under longitudinal seismic excitation. The in-plane bending moment caused by the lower chord at the vault is 4.2–5.5 times of the corresponding bending moment under the longitudinal seismic excitation. For the bottom chord of arch rib, the arch foot is the weak part of earthquake resistance, but for the upper chord of arch rib, the arch foot, arch crown and the intersection of column and upper chord can all be the potential earthquake-resistant weak parts. The normal stress of the bottom chord of the arch rib under multidimensional excitation is mainly caused by the axial force, but the normal stress of the upper chord of the arch rib is caused by the axial force, in-plane and out of plane bending moment.Originality/valueThe research provides specific suggestions for ground motion excitation mode and also provides reference information for the earthquake-resistant weak part and seismic design of long-span deck type railway steel truss arch bridges.","PeriodicalId":369838,"journal":{"name":"Railway Sciences","volume":"72 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Railway Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1108/rs-04-2022-0005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

PurposeUnder different ground motion excitation modes, the spatial coupling effect of seismic response for the arch bridge with thrust, seismic weak parts and the internal force components of the control section of main arch ribs are analyzed.Design/methodology/approachTaking a 490 m deck type railway steel truss arch bridge as the background, the dynamic calculation model of the whole bridge was established by SAP2000 software. The seismic response analyses under one-, two- and three-dimension (1D, 2D and 3D) uniform ground motion excitations were carried out.FindingsFor the steel truss arch bridge composed of multiple arch ribs, any single direction ground motion excitation will cause large axial force in the chord of arch rib. The axial force caused by transverse and vertical ground motion excitation in the chord of arch crown area is 1.4–3.6 times of the corresponding axial force under longitudinal seismic excitation. The in-plane bending moment caused by the lower chord at the vault is 4.2–5.5 times of the corresponding bending moment under the longitudinal seismic excitation. For the bottom chord of arch rib, the arch foot is the weak part of earthquake resistance, but for the upper chord of arch rib, the arch foot, arch crown and the intersection of column and upper chord can all be the potential earthquake-resistant weak parts. The normal stress of the bottom chord of the arch rib under multidimensional excitation is mainly caused by the axial force, but the normal stress of the upper chord of the arch rib is caused by the axial force, in-plane and out of plane bending moment.Originality/valueThe research provides specific suggestions for ground motion excitation mode and also provides reference information for the earthquake-resistant weak part and seismic design of long-span deck type railway steel truss arch bridges.
多维激励下具有推力的大跨钢桁架拱桥的地震反应
目的在不同地震动激励方式下,分析了推力、地震薄弱部位和主拱肋控制截面内力分量对拱桥地震反应的空间耦合效应。设计/方法/方法以某490m甲板式铁路钢桁架拱桥为背景,利用SAP2000软件建立了整座桥的动力计算模型。进行了一维、二维和三维(1D、2D和3D)均匀地震动激励下的地震反应分析。研究结果对于由多个拱肋组成的钢桁架拱桥,任何单向地震动激励都会在拱肋弦部产生较大的轴向力。拱冠区弦部横向和纵向地震动激励产生的轴向力是纵向地震激励下相应轴向力的1.4 ~ 3.6倍。拱顶处下弦引起的面内弯矩是纵向地震作用下相应弯矩的4.2 ~ 5.5倍。对于拱肋下弦,拱脚是抗震薄弱部位,而对于拱肋上弦,拱脚、拱顶以及柱与上弦的交点都可以是潜在的抗震薄弱部位。多维激励下拱肋下弦的法向应力主要由轴向力引起,而拱肋上弦的法向应力主要由轴向力、面内和面外弯矩引起。本研究对地震动激励方式提出了具体的建议,也为大跨面式铁路钢桁架拱桥的抗震薄弱部分和抗震设计提供了参考信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信