{"title":"Application of on-line versus off-line PD testing for stator insulation monitoring","authors":"H. Zhu, V. Green, D. Huynh","doi":"10.1109/EEIC.1999.826202","DOIUrl":null,"url":null,"abstract":"Partial discharge testing can effectively diagnose insulation problems in the stator winding of high-voltage generators and motors, since partial discharges are a symptom of most insulation failure mechanisms. Partial discharge testing can be performed either when the machine is not operating (offline) or during normal machine operation (on-line). Off-line PD testing is a well-known method to assess the stator winding insulation. Over ten years, on-line PD testing has proven to be a successful technique of monitoring stator insulation condition to forewarn plant personnel of possible machine failures and to help them implement a predictive maintenance program. This paper presents an on-line and off-line PD test on a hydro-generator using the same test instrument and sensors. A comparison of the two tests indicates that the off-line test results are consistent with the on-line test results. Similarities and differences of the on-line and off-line PD tests are discussed.","PeriodicalId":415071,"journal":{"name":"Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference (Cat. No.99CH37035)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference (Cat. No.99CH37035)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEIC.1999.826202","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
Partial discharge testing can effectively diagnose insulation problems in the stator winding of high-voltage generators and motors, since partial discharges are a symptom of most insulation failure mechanisms. Partial discharge testing can be performed either when the machine is not operating (offline) or during normal machine operation (on-line). Off-line PD testing is a well-known method to assess the stator winding insulation. Over ten years, on-line PD testing has proven to be a successful technique of monitoring stator insulation condition to forewarn plant personnel of possible machine failures and to help them implement a predictive maintenance program. This paper presents an on-line and off-line PD test on a hydro-generator using the same test instrument and sensors. A comparison of the two tests indicates that the off-line test results are consistent with the on-line test results. Similarities and differences of the on-line and off-line PD tests are discussed.