{"title":"A detailed pumped storage station model for power system analysis","authors":"H.M. Gao, C. Wang","doi":"10.1109/PES.2006.1709259","DOIUrl":null,"url":null,"abstract":"In the pumped storage stations, the operating point of reversible pump turbine and the water flow direction in conduit system often change. There is no detailed pumped storage station model in present commercial power system simulation software. The ideal hydro turbine model can only be applied under the generating operating condition, but can't be applied under the pumped operating condition, the conversion of operating condition, large disturbance simulation, and so on. In this paper, a new detailed pumped storage station model is established by the PSS/E user-written model: The reversible pump turbine is represented by the improved SUTER transform characteristics model, which is based on the four-quadrant operating characteristics. And the conduit system is represented by the versatile model. Based on the PSS/E power system models, the generating operating condition, the pumped operating condition, the conversion of operating condition and large disturbance can all be simulated. The application of this model to the test systems is carried out and the results show that the pumped storage station model is valid","PeriodicalId":267582,"journal":{"name":"2006 IEEE Power Engineering Society General Meeting","volume":"103 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE Power Engineering Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PES.2006.1709259","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

In the pumped storage stations, the operating point of reversible pump turbine and the water flow direction in conduit system often change. There is no detailed pumped storage station model in present commercial power system simulation software. The ideal hydro turbine model can only be applied under the generating operating condition, but can't be applied under the pumped operating condition, the conversion of operating condition, large disturbance simulation, and so on. In this paper, a new detailed pumped storage station model is established by the PSS/E user-written model: The reversible pump turbine is represented by the improved SUTER transform characteristics model, which is based on the four-quadrant operating characteristics. And the conduit system is represented by the versatile model. Based on the PSS/E power system models, the generating operating condition, the pumped operating condition, the conversion of operating condition and large disturbance can all be simulated. The application of this model to the test systems is carried out and the results show that the pumped storage station model is valid
一种用于电力系统分析的抽水蓄能电站详细模型
在抽水蓄能电站中,可逆水泵水轮机的工作点和管道系统中的水流方向经常发生变化。目前商用电力系统仿真软件中没有详细的抽水蓄能电站模型。理想的水轮机模型只能应用于发电工况,而不能应用于抽水工况、工况转换、大扰动模拟等工况。本文采用PSS/E用户自写模型建立了一种新的抽水蓄能电站详细模型:基于四象限运行特性的改进型SUTER变换特性模型表示可逆泵水轮机。导管系统用通用性模型表示。基于PSS/E电力系统模型,可以对发电工况、泵送工况、工况转换工况和大扰动进行模拟。将该模型应用于试验系统,结果表明该模型是有效的
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信