J. Eidson, Andrew Fernandez, Bruce Hamilton, Jad Naous, Dieter Vook
{"title":"Spider transparent clock","authors":"J. Eidson, Andrew Fernandez, Bruce Hamilton, Jad Naous, Dieter Vook","doi":"10.1109/ISPCS.2008.4659204","DOIUrl":null,"url":null,"abstract":"This paper discusses a device, the spider transparent clock, which can be used to retrofit existing bridges and routers to allow them to deliver highly accurate time using the IEEE 1588 protocol. The spider transparent clock corrects for the internal queuing jitter and asymmetry introduced by these bridges and routers.","PeriodicalId":428276,"journal":{"name":"2008 IEEE International Symposium on Precision Clock Synchronization for Measurement, Control and Communication","volume":"84 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 IEEE International Symposium on Precision Clock Synchronization for Measurement, Control and Communication","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISPCS.2008.4659204","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11
Abstract
This paper discusses a device, the spider transparent clock, which can be used to retrofit existing bridges and routers to allow them to deliver highly accurate time using the IEEE 1588 protocol. The spider transparent clock corrects for the internal queuing jitter and asymmetry introduced by these bridges and routers.