{"title":"A Reduced-Order Technique for Stability Investigation of Voltage Source Inverters","authors":"Aswad Adib, Fariba Fateh, M. Shadmand, B. Mirafzal","doi":"10.1109/ECCE.2018.8557517","DOIUrl":null,"url":null,"abstract":"This paper presents a second order model for stability analysis of grid-connected voltage source inverters (VSIs). VSIs are commonly modeled as ideal voltage sources for analysis. However, this approach cannot guarantee accuracy since it does not take into consideration the dominant states of the inverter. In this paper, a reduced-order model based on balanced truncation method is derived from a comprehensive twelfth-order model for a grid-connected VSI. The developed second-order model is computationally modest while providing an accurate representation of the system characteristic. The efficacy of the developed model is verified through time-domain simulations and root locus studies of the model eigenvalues against its full-order counterpart.","PeriodicalId":415217,"journal":{"name":"2018 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Energy Conversion Congress and Exposition (ECCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE.2018.8557517","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

This paper presents a second order model for stability analysis of grid-connected voltage source inverters (VSIs). VSIs are commonly modeled as ideal voltage sources for analysis. However, this approach cannot guarantee accuracy since it does not take into consideration the dominant states of the inverter. In this paper, a reduced-order model based on balanced truncation method is derived from a comprehensive twelfth-order model for a grid-connected VSI. The developed second-order model is computationally modest while providing an accurate representation of the system characteristic. The efficacy of the developed model is verified through time-domain simulations and root locus studies of the model eigenvalues against its full-order counterpart.
电压源逆变器稳定性研究的降阶技术
提出了一种用于并网电压源逆变器稳定性分析的二阶模型。vsi通常被建模为分析的理想电压源。然而,这种方法不能保证精度,因为它没有考虑逆变器的主导状态。本文从并网VSI的12阶综合模型出发,导出了基于平衡截断法的降阶模型。所建立的二阶模型在提供系统特性的精确表示的同时,在计算上是适度的。通过时域仿真和模型特征值相对于其全阶对应的根轨迹研究,验证了所开发模型的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信