Removal of chemical oxygen demand (COD) from hospital wastewater by electro fenton process using graphite–graphite electrochemical system

Abdullah Yasser Gijir, A. Abbar
{"title":"Removal of chemical oxygen demand (COD) from hospital wastewater by electro fenton process using graphite–graphite electrochemical system","authors":"Abdullah Yasser Gijir, A. Abbar","doi":"10.30772/qjes.v15i1.817","DOIUrl":null,"url":null,"abstract":"Removal of COD from hospital wastewater generated from Al- Diwaniyah hospital located in Iraq was achieved using graphite–graphite electro-Fenton (EF) system. The effect of various operational parameters on the COD removal efficiency was investigated based on response surface methodology (RSM). Optimal conditions were the current density of 20mA/cm2, FeSO4 concentration of, and time of  It achieved a COD elimination efficiency of 97.964 % at a specific energy consumption of 10.78 kWh/kg. The results indicated that time had the least effect on the efficiency with which chemical oxygen demand is eliminated, however, the share of current density had the greatest effect, followed by the FeSO4 concentration. The adequacy of the model equation was confirmed by its high R2 value (99.62%). The present study shows that the graphite–graphite EF system was an efficient tool for removing COD from hospital wastewaters.","PeriodicalId":227530,"journal":{"name":"Al-Qadisiyah Journal for Engineering Sciences","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Al-Qadisiyah Journal for Engineering Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30772/qjes.v15i1.817","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Removal of COD from hospital wastewater generated from Al- Diwaniyah hospital located in Iraq was achieved using graphite–graphite electro-Fenton (EF) system. The effect of various operational parameters on the COD removal efficiency was investigated based on response surface methodology (RSM). Optimal conditions were the current density of 20mA/cm2, FeSO4 concentration of, and time of  It achieved a COD elimination efficiency of 97.964 % at a specific energy consumption of 10.78 kWh/kg. The results indicated that time had the least effect on the efficiency with which chemical oxygen demand is eliminated, however, the share of current density had the greatest effect, followed by the FeSO4 concentration. The adequacy of the model equation was confirmed by its high R2 value (99.62%). The present study shows that the graphite–graphite EF system was an efficient tool for removing COD from hospital wastewaters.
石墨-石墨电化学系统电fenton法去除医院废水中的化学需氧量(COD
采用石墨-石墨电fenton (EF)系统对伊拉克Al- Diwaniyah医院废水中的COD进行了去除。基于响应面法(RSM)研究了不同操作参数对COD去除率的影响。最优条件为电流密度为20mA/cm2, FeSO4浓度为,时间为,比能耗为10.78 kWh/kg, COD去除率为97.964%。结果表明,时间对化学需氧量消除效率的影响最小,电流密度对化学需氧量消除效率的影响最大,其次是FeSO4浓度。模型方程的高R2值(99.62%)证实了模型方程的充分性。本研究表明,石墨-石墨EF系统是去除医院废水中COD的有效工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信