{"title":"Scan acceleration","authors":"S. Kozerke, R. Boubertakh, M. Miquel","doi":"10.1093/med/9780198779735.003.0004","DOIUrl":null,"url":null,"abstract":"In cardiovascular magnetic resonance imaging, scan time is of critical importance, as many applications require breath-holding to suppress respiratory-related image artefacts. In this chapter, approaches to reduce scan time, while maintaining resolution, are described. Besides partial sampling of k-space, non-Cartesian k-space trajectories are introduced, followed by an overview of data under-sampling techniques as they are implemented on clinical magnetic resonance systems. Advantages and limitations of each of these methods are briefly described.","PeriodicalId":294042,"journal":{"name":"The EACVI Textbook of Cardiovascular Magnetic Resonance","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The EACVI Textbook of Cardiovascular Magnetic Resonance","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/med/9780198779735.003.0004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In cardiovascular magnetic resonance imaging, scan time is of critical importance, as many applications require breath-holding to suppress respiratory-related image artefacts. In this chapter, approaches to reduce scan time, while maintaining resolution, are described. Besides partial sampling of k-space, non-Cartesian k-space trajectories are introduced, followed by an overview of data under-sampling techniques as they are implemented on clinical magnetic resonance systems. Advantages and limitations of each of these methods are briefly described.
扫描加速度
在心血管磁共振成像中,扫描时间是至关重要的,因为许多应用需要屏气来抑制呼吸相关的图像伪影。在本章中,描述了在保持分辨率的同时减少扫描时间的方法。除了k空间的部分采样外,还介绍了非笛卡尔k空间轨迹,然后概述了在临床磁共振系统中实施的数据欠采样技术。简要描述了每种方法的优点和局限性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信