Stacked, parallel-plate solid-dielectric Blumlein lines for compact pulsed power

M. Domonkos, J. O'Loughlin, T. Tran, P. Turchi, Darwin Brown, C. W. Gregg, J. Parker, T. Montoya, K. Slenes
{"title":"Stacked, parallel-plate solid-dielectric Blumlein lines for compact pulsed power","authors":"M. Domonkos, J. O'Loughlin, T. Tran, P. Turchi, Darwin Brown, C. W. Gregg, J. Parker, T. Montoya, K. Slenes","doi":"10.1109/PPPS.2007.4345674","DOIUrl":null,"url":null,"abstract":"The stacked Blumlein line is a concept that has been touted as a highly compact pulsed power system because it combines the functions of energy storage, voltage scaling, and pulse shaping into a single sub-system. As a result, two single stage Blumlein lines have been fabricated and tested using a polymer-ceramic composite dielectric. Examination of the breakdown of the dielectric near the DC voltage specification led to the understanding of the degree of voltage reversal experienced by the lines. Voltage reversal is compounded in a stacked arrangement. The voltage reversal and transients induced by the switch jitter in a stacked configuration require significant derating of the dielectric strength. Consequently, the system must be operated much below the intrinsic dielectric energy density, compromising efforts to design a compact pulsed power system. This paper presents the conclusion that for derating below 0.72, as is likely necessary, a stacked Blumlein line will contain more dielectric than a comparable stacked transmission line.","PeriodicalId":275106,"journal":{"name":"2007 16th IEEE International Pulsed Power Conference","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 16th IEEE International Pulsed Power Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPPS.2007.4345674","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The stacked Blumlein line is a concept that has been touted as a highly compact pulsed power system because it combines the functions of energy storage, voltage scaling, and pulse shaping into a single sub-system. As a result, two single stage Blumlein lines have been fabricated and tested using a polymer-ceramic composite dielectric. Examination of the breakdown of the dielectric near the DC voltage specification led to the understanding of the degree of voltage reversal experienced by the lines. Voltage reversal is compounded in a stacked arrangement. The voltage reversal and transients induced by the switch jitter in a stacked configuration require significant derating of the dielectric strength. Consequently, the system must be operated much below the intrinsic dielectric energy density, compromising efforts to design a compact pulsed power system. This paper presents the conclusion that for derating below 0.72, as is likely necessary, a stacked Blumlein line will contain more dielectric than a comparable stacked transmission line.
用于紧凑脉冲电源的叠置平行板固体介质布卢姆莱恩线
堆叠Blumlein线是一种被吹捧为高度紧凑的脉冲电源系统的概念,因为它将能量存储、电压缩放和脉冲整形功能结合到一个子系统中。因此,使用聚合物-陶瓷复合电介质制备了两个单级Blumlein线并进行了测试。检查介电介质在直流电压规范附近的击穿情况,可以了解线路所经历的电压反转程度。电压反转是叠加在一起的。在堆叠结构中,由开关抖动引起的电压反转和瞬态需要显著的介电强度降额。因此,系统必须在远低于固有介电能量密度的情况下运行,从而降低了设计紧凑脉冲功率系统的努力。本文提出的结论是,当降额低于0.72时,很可能是必要的,堆叠的Blumlein线将比类似的堆叠传输线包含更多的介电。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信