{"title":"Reduced common-mode voltage in Z-Source Inverters","authors":"N. Noroozi, M. Zolghadri, M. Yaghoubi","doi":"10.1109/PEDSTC.2017.7910361","DOIUrl":null,"url":null,"abstract":"Z-source family has been widespread in photovoltaic (PV) applications. In trasformerless grid-connected PV systems, the common mode voltage (CMV) time variations, cause the leakage current flow. This current flows through the stray capacitance of the PV panels. For a Z-Source Inverter (ZSI), the CMV would have higher high-frequency harmonics, due to the shoot through states within the switching cycles. In this paper, the CMV of a ZSI is analyzed and a simple method is proposed for the harmonic reduction of the CMV in the ZSI. The CMV reduction method is based on changing the switching states. The CMV in reduced method is compared to the CMV in the traditional ZSI in frequency domain by using modulated Fourier transform (MFT) method. The results are verified through the simulation of a 1kw ZSI.","PeriodicalId":414828,"journal":{"name":"2017 8th Power Electronics, Drive Systems & Technologies Conference (PEDSTC)","volume":"113 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 8th Power Electronics, Drive Systems & Technologies Conference (PEDSTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDSTC.2017.7910361","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Z-source family has been widespread in photovoltaic (PV) applications. In trasformerless grid-connected PV systems, the common mode voltage (CMV) time variations, cause the leakage current flow. This current flows through the stray capacitance of the PV panels. For a Z-Source Inverter (ZSI), the CMV would have higher high-frequency harmonics, due to the shoot through states within the switching cycles. In this paper, the CMV of a ZSI is analyzed and a simple method is proposed for the harmonic reduction of the CMV in the ZSI. The CMV reduction method is based on changing the switching states. The CMV in reduced method is compared to the CMV in the traditional ZSI in frequency domain by using modulated Fourier transform (MFT) method. The results are verified through the simulation of a 1kw ZSI.
降低z源逆变器的共模电压
z源族在光伏(PV)应用中得到了广泛的应用。在无变压器并网光伏系统中,共模电压(CMV)随时间变化,会导致漏电电流的产生。该电流流过PV板的杂散电容。对于z源逆变器(ZSI),由于开关周期内的穿透状态,CMV将具有更高的高频谐波。本文对ZSI的CMV进行了分析,提出了一种降低ZSI中CMV谐波的简单方法。CMV的减少方法是基于改变开关状态。利用调制傅里叶变换(MFT)方法,在频域将约简方法中的CMV与传统ZSI中的CMV进行了比较。通过1kw ZSI的仿真验证了上述结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信