Type of Cell Separator, Fenwal Amicus Vs COBE Spectra LRS, May Influence the Corpuscular Elements Value of the Donor`s Blood (SN-ICFC Procedure)

Elvedin Landžo, A. Bajraktarević, Vesna Cetkovic
{"title":"Type of Cell Separator, Fenwal Amicus Vs COBE Spectra LRS, May Influence the Corpuscular Elements Value of the Donor`s Blood (SN-ICFC Procedure)","authors":"Elvedin Landžo, A. Bajraktarević, Vesna Cetkovic","doi":"10.5455/ijbh.2022.10.155-159","DOIUrl":null,"url":null,"abstract":"Background: During the plateletpheresis procedure the number of thrombocytes in the donor’s blood significantly decreases, and the levels of the hematocrit, hemoglobin, and leukocyte diminish as well. Influence of the cell separator is one of the factors that affects the levels of HCT, Hgb and WBC. Objective: In this study, the goal was to determine the value difference of HCT, Hgb, WBC, and platelets after the platelet pheresis process between performance on Fenwal AMICUS and on COBE Spectra LRS Methods: The criteria for participation: male in the age range of 25-45. We have formed two groups: group I–180 separation were performed on 60 participants were the values of hematocrits, concentration of hemoglobin and number of leukocytes ware established before and after separation using the single-needle intermitent flow cell separation (SN-IFCS) on the Fenwal AMICUS device. Group II – presented 180 separation that were performed on 60 participants, were the values of hematocrits, concentration of hemoglobin and number of leukocytes ware established before and after separation using double-needle continuous flow cell separation (SN-IFCS) on the COBE Spectra LRS. device. To confirm the statistical differences we have used Student t-test for independent or dependent samples, as well as Mann-Whitney U test as non-parametric alternative. To compare differences between the values of four parameters (P1-P2) from two groups (using two devices–Fenwal AMICUS and Fresenius Com Tec) we have performed the ANOVA variance analyze. The possibility of errors were accepted for α<0,05, and the difference between groups as statistical relevant were accepted for p<0,05. Results Statistically significant lower values were noted for all researched parameters after separation on both devices (Fenwal AMICUS and COBE Spectra LRS). Comparing the parameters of hematocrit, leukocytes and hemoglobin’s, we found a statistical significant difference in the decrease of the parameter’s value after separation, there was a significant decrease change in using COBE Spectra LRS cell separator compared to using Fenwal AMICUS cell separator with the same procedure. For the platelets (Plt) there was no statistical significant difference (p> 0,05-α=0,05), between average level obtained using either Fenwal AMICUS or COBE Spectra LRS. Conclusion: The type of cell separator had the influence on the decrease value of the observed parameters.","PeriodicalId":187078,"journal":{"name":"International Journal on Biomedicine and Healthcare","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal on Biomedicine and Healthcare","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5455/ijbh.2022.10.155-159","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: During the plateletpheresis procedure the number of thrombocytes in the donor’s blood significantly decreases, and the levels of the hematocrit, hemoglobin, and leukocyte diminish as well. Influence of the cell separator is one of the factors that affects the levels of HCT, Hgb and WBC. Objective: In this study, the goal was to determine the value difference of HCT, Hgb, WBC, and platelets after the platelet pheresis process between performance on Fenwal AMICUS and on COBE Spectra LRS Methods: The criteria for participation: male in the age range of 25-45. We have formed two groups: group I–180 separation were performed on 60 participants were the values of hematocrits, concentration of hemoglobin and number of leukocytes ware established before and after separation using the single-needle intermitent flow cell separation (SN-IFCS) on the Fenwal AMICUS device. Group II – presented 180 separation that were performed on 60 participants, were the values of hematocrits, concentration of hemoglobin and number of leukocytes ware established before and after separation using double-needle continuous flow cell separation (SN-IFCS) on the COBE Spectra LRS. device. To confirm the statistical differences we have used Student t-test for independent or dependent samples, as well as Mann-Whitney U test as non-parametric alternative. To compare differences between the values of four parameters (P1-P2) from two groups (using two devices–Fenwal AMICUS and Fresenius Com Tec) we have performed the ANOVA variance analyze. The possibility of errors were accepted for α<0,05, and the difference between groups as statistical relevant were accepted for p<0,05. Results Statistically significant lower values were noted for all researched parameters after separation on both devices (Fenwal AMICUS and COBE Spectra LRS). Comparing the parameters of hematocrit, leukocytes and hemoglobin’s, we found a statistical significant difference in the decrease of the parameter’s value after separation, there was a significant decrease change in using COBE Spectra LRS cell separator compared to using Fenwal AMICUS cell separator with the same procedure. For the platelets (Plt) there was no statistical significant difference (p> 0,05-α=0,05), between average level obtained using either Fenwal AMICUS or COBE Spectra LRS. Conclusion: The type of cell separator had the influence on the decrease value of the observed parameters.
细胞分离器类型,Fenwal Amicus Vs COBE光谱LRS,可能影响供者血液的红细胞元素值(SN-ICFC程序)
背景:在采血小板过程中,供者血液中血小板的数量显著减少,红细胞比容、血红蛋白和白细胞的水平也减少。细胞分离器的影响是影响HCT、Hgb和WBC水平的因素之一。目的:在本研究中,目的是确定在Fenwal AMICUS和COBE Spectra LRS上表现的血小板采后HCT、Hgb、WBC和血小板的值差异。方法:参加标准:25-45岁的男性。我们分为两组:I-180组对60名受试者进行分离,分别在Fenwal AMICUS装置上使用单针间歇流式细胞分离(SN-IFCS)测定分离前后的红细胞比容、血红蛋白浓度和白细胞数量。第II组,60例患者进行180次分离,分别是在COBE Spectra LRS上采用双针连续流式细胞分离(SN-IFCS)分离前后的红细胞比容、血红蛋白浓度和白细胞数量。设备。为了确认统计差异,我们使用独立或依赖样本的学生t检验,以及Mann-Whitney U检验作为非参数替代。为了比较两组(使用fenwal AMICUS和Fresenius Com Tec两种设备)的四个参数(P1-P2)值之间的差异,我们进行了方差分析。在使用Fenwal AMICUS或COBE Spectra LRS获得的平均水平之间,α 0.05 -α= 0.05可以接受误差的可能性。结论:细胞分离器的类型对观察参数的减小值有影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信