Identification and correction of artefact in the measurement of pulsed magnetic fields

G. Crotti, L. Giaccone, D. Giordano
{"title":"Identification and correction of artefact in the measurement of pulsed magnetic fields","authors":"G. Crotti, L. Giaccone, D. Giordano","doi":"10.1109/CPEM.2016.7540792","DOIUrl":null,"url":null,"abstract":"AC magnetic flux density meters usually integrate a high pass filter with a very low cut-off frequency (1 Hz-30 Hz) aiming at reducing the effect of slow oscillations. This can distort the actual time domain behaviour of induction waveforms detectable close to industrial or medical devices, even causing artefact high amplitude oscillations. This paper proposes a procedure to identify the filter parameters that accurately reproduce its measured frequency behaviour and suggests an algorithm to correct, in time domain, the field meter recorded waveform.","PeriodicalId":415488,"journal":{"name":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","volume":"43 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.2016.7540792","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

AC magnetic flux density meters usually integrate a high pass filter with a very low cut-off frequency (1 Hz-30 Hz) aiming at reducing the effect of slow oscillations. This can distort the actual time domain behaviour of induction waveforms detectable close to industrial or medical devices, even causing artefact high amplitude oscillations. This paper proposes a procedure to identify the filter parameters that accurately reproduce its measured frequency behaviour and suggests an algorithm to correct, in time domain, the field meter recorded waveform.
脉冲磁场测量中伪影的识别与校正
交流磁通密度计通常集成一个高通滤波器,其截止频率非常低(1 Hz-30 Hz),旨在减少慢振荡的影响。这可能会扭曲接近工业或医疗设备的感应波形的实际时域行为,甚至导致人工高振幅振荡。本文提出了一种方法来识别能准确再现其测量频率行为的滤波器参数,并提出了一种在时域内校正现场仪表记录波形的算法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信