{"title":"Forced convection heat transfer of a vertical shrouded fin array","authors":"M. Chyu, L. Wu, J. Murthy","doi":"10.1109/ITHERM.1988.28683","DOIUrl":null,"url":null,"abstract":"Summary form only given. The detailed local distribution is obtained of the convective heat transfer coefficient on the fin structure. A mass transfer system using the naphthalene sublimation technique is chosen for the study. The test model is fabricated by coating a layer of naphthalene on the fin surface; this gives the surface an equivalence to the isothermal boundary condition in heat transfer. This also implies that the fin array has 100% of fin efficiency. A state-of-the-art, computer-automated measurement system is used to acquire the naphthalene surface profiles before and after the surface exposure to the air stream in a wind tunnel. The present test uses fixed values of fin height-to-space ratio (approximately 1.5) and the streamwise dimension (approximately 5 fin heights).<<ETX>>","PeriodicalId":226424,"journal":{"name":"InterSociety Conference on Thermal Phenomena in the Fabrication and Operation of Electronic Components. I-THERM '88","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"InterSociety Conference on Thermal Phenomena in the Fabrication and Operation of Electronic Components. I-THERM '88","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITHERM.1988.28683","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Summary form only given. The detailed local distribution is obtained of the convective heat transfer coefficient on the fin structure. A mass transfer system using the naphthalene sublimation technique is chosen for the study. The test model is fabricated by coating a layer of naphthalene on the fin surface; this gives the surface an equivalence to the isothermal boundary condition in heat transfer. This also implies that the fin array has 100% of fin efficiency. A state-of-the-art, computer-automated measurement system is used to acquire the naphthalene surface profiles before and after the surface exposure to the air stream in a wind tunnel. The present test uses fixed values of fin height-to-space ratio (approximately 1.5) and the streamwise dimension (approximately 5 fin heights).<>