disp2ppg: Pulse Wave Generation to PPG Sensor using Display

Atsuhiro Fujii, Kazuya Murao, N. Matsuhisa
{"title":"disp2ppg: Pulse Wave Generation to PPG Sensor using Display","authors":"Atsuhiro Fujii, Kazuya Murao, N. Matsuhisa","doi":"10.1145/3460421.3478823","DOIUrl":null,"url":null,"abstract":"Wearable devices are often used to record the user’s biometric information. Among biometric data, pulse data has been used in methods such as heart rate monitoring and emotion estimation. The most common type of pulse sensor is the photoplethysmogram (PPG), which irradiates a green LED on the skin and measures pulse data from changes in the light reflected through the blood vessels. PPG sensors have been implemented in commercially available wearable devices such as smartwatches. When a smartwatch is worn on an artificial body such as a prosthetic hand or a robotic arm, correct data cannot be acquired because there is no blood flow. In this study, we propose a method that enables the PPG sensor to measure arbitrary pulse data using a display. If this method is successful, it will be possible to input pulse data measured at the junction of the live body and the prosthetic hand to the display, and have the smartwatch attached to the prosthetic hand read the same pulse data. In this paper, we focus on the heart rate and report the results of an experiment in which a target heart rate was input and the display was controlled to determine whether the target heart rate could be obtained by a smartwatch. We implemented a display drawing program and conducted the evaluation using five kinds of smartwatches and four kinds of displays. Results showed that the error between the target heart rate and the heart rate acquired by the smartwatch was within ± 3 beats per minute in many cases.","PeriodicalId":395295,"journal":{"name":"Proceedings of the 2021 ACM International Symposium on Wearable Computers","volume":"110 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2021 ACM International Symposium on Wearable Computers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3460421.3478823","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Wearable devices are often used to record the user’s biometric information. Among biometric data, pulse data has been used in methods such as heart rate monitoring and emotion estimation. The most common type of pulse sensor is the photoplethysmogram (PPG), which irradiates a green LED on the skin and measures pulse data from changes in the light reflected through the blood vessels. PPG sensors have been implemented in commercially available wearable devices such as smartwatches. When a smartwatch is worn on an artificial body such as a prosthetic hand or a robotic arm, correct data cannot be acquired because there is no blood flow. In this study, we propose a method that enables the PPG sensor to measure arbitrary pulse data using a display. If this method is successful, it will be possible to input pulse data measured at the junction of the live body and the prosthetic hand to the display, and have the smartwatch attached to the prosthetic hand read the same pulse data. In this paper, we focus on the heart rate and report the results of an experiment in which a target heart rate was input and the display was controlled to determine whether the target heart rate could be obtained by a smartwatch. We implemented a display drawing program and conducted the evaluation using five kinds of smartwatches and four kinds of displays. Results showed that the error between the target heart rate and the heart rate acquired by the smartwatch was within ± 3 beats per minute in many cases.
dis2ppg:脉冲波产生到使用显示器的PPG传感器
可穿戴设备通常用于记录用户的生物特征信息。在生物特征数据中,脉搏数据已被用于心率监测和情绪估计等方法。最常见的脉冲传感器类型是光电容积描记仪(PPG),它在皮肤上照射绿色LED,并测量通过血管反射的光的变化的脉冲数据。PPG传感器已经应用于商用可穿戴设备,如智能手表。如果将智能手表戴在假手或机械臂等人造身体上,由于没有血液流动,无法获得正确的数据。在这项研究中,我们提出了一种方法,使PPG传感器测量任意脉冲数据使用显示器。如果这种方法成功,将有可能将在活体和假手交界处测量的脉搏数据输入到显示器上,并让附着在假手上的智能手表读取相同的脉搏数据。在本文中,我们以心率为重点,报告了一个实验的结果,在这个实验中,我们输入一个目标心率,并控制显示,以确定智能手表是否可以获得目标心率。我们实施了一个显示绘图程序,并使用五种智能手表和四种显示进行了评估。结果表明,在许多情况下,目标心率与智能手表获取的心率之间的误差在±3次/分钟以内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信