Study on the transmission capacity and voltage stability of weak back-to-back HVDC system

Liu Peng
{"title":"Study on the transmission capacity and voltage stability of weak back-to-back HVDC system","authors":"Liu Peng","doi":"10.1109/PES.2004.1373111","DOIUrl":null,"url":null,"abstract":"This Paper first studies the transmission power and stability limit of AC link system without reactive power compensation, and then studies the transmission power and stability limit of weak HVDC link system without reactive power compensation, as well as the impact of both the changes of AC reactance and the rectifier angle and inverter extinguisher angle on the transmission power and voltage stability. This paper holds that, in a weak back-to-back HVDC system without reactive power compensation, the increase of AC line reactance as well as the increase of the rectifier angle and inverter extinguisher angle will reduce the transmission capability and voltage stability, or even lead to voltage collapse","PeriodicalId":236779,"journal":{"name":"IEEE Power Engineering Society General Meeting, 2004.","volume":"236 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Power Engineering Society General Meeting, 2004.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PES.2004.1373111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

This Paper first studies the transmission power and stability limit of AC link system without reactive power compensation, and then studies the transmission power and stability limit of weak HVDC link system without reactive power compensation, as well as the impact of both the changes of AC reactance and the rectifier angle and inverter extinguisher angle on the transmission power and voltage stability. This paper holds that, in a weak back-to-back HVDC system without reactive power compensation, the increase of AC line reactance as well as the increase of the rectifier angle and inverter extinguisher angle will reduce the transmission capability and voltage stability, or even lead to voltage collapse
弱背靠背直流输电系统的输电容量与电压稳定性研究
本文首先研究无功补偿时交流链路系统的传输功率和稳定极限,然后研究无功补偿时弱HVDC链路系统的传输功率和稳定极限,以及交流电抗和整流角、逆变灭火器角的变化对传输功率和电压稳定的影响。本文认为,在无功补偿的弱背对背高压直流系统中,交流线路电抗的增大以及整流角和逆变灭火器角的增大会降低输电能力和电压稳定性,甚至导致电压崩溃
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信