{"title":"An AC TO AC converter improved in input current harmonics and power factor","authors":"Teruo Tanaka, H. Kasahara","doi":"10.1109/PESC.1979.7081027","DOIUrl":null,"url":null,"abstract":"This paper is on an AC/AC converter which converts a three phase line frequency power to a single phase of a higher frequency for induction heating. It is a single conversion system in contrast to a widely known double conversion system; AC/DC/AC. But the latter system has two disadvantages; (1) Input line harmonics are so large (especially under power control by DC voltage regulation) that it is difficult to incorporate an effective harmonic filter network. (2) It has a power factor of lag and decreases in the further lagging direction in power control. In contrast, the AC/AC converter system presented here in Figure 1 or 2 has some good features, without reducing conversion efficiency. The commutation scheme is shown in Figures 3 and 5, and is similar to those presented in papers [1] — [3]. But the new method is further improved especially in the above-mentioned features.","PeriodicalId":101593,"journal":{"name":"1979 IEEE Power Electronics Specialists Conference","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1979-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1979 IEEE Power Electronics Specialists Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1979.7081027","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
This paper is on an AC/AC converter which converts a three phase line frequency power to a single phase of a higher frequency for induction heating. It is a single conversion system in contrast to a widely known double conversion system; AC/DC/AC. But the latter system has two disadvantages; (1) Input line harmonics are so large (especially under power control by DC voltage regulation) that it is difficult to incorporate an effective harmonic filter network. (2) It has a power factor of lag and decreases in the further lagging direction in power control. In contrast, the AC/AC converter system presented here in Figure 1 or 2 has some good features, without reducing conversion efficiency. The commutation scheme is shown in Figures 3 and 5, and is similar to those presented in papers [1] — [3]. But the new method is further improved especially in the above-mentioned features.
本文介绍了一种AC/AC变换器,它将三相线频电源转换成更高频率的单相电源,用于感应加热。它是一种单一的转换系统,而不是众所周知的双重转换系统;AC / DC / AC。但后一种制度有两个缺点;(1)输入线路谐波太大(特别是在直流稳压控制下),难以纳入有效的谐波滤波网络。(2)具有滞后的功率因数,并且在功率控制中沿进一步滞后方向减小。相比之下,图1或2中所示的AC/AC变换器系统具有一些良好的特性,但不会降低转换效率。换相方案如图3和图5所示,与文献[1]-[3]相似。但新方法在上述特点上有了进一步的改进。