Application of a digital prototype for CT-based bone strength analysis

O. Gerasimov, Karina Sharafutdinova, Ramil R. Rakhmatullin, T. Baltina, M. Baltin, A. Fedianin
{"title":"Application of a digital prototype for CT-based bone strength analysis","authors":"O. Gerasimov, Karina Sharafutdinova, Ramil R. Rakhmatullin, T. Baltina, M. Baltin, A. Fedianin","doi":"10.1109/ITNT55410.2022.9848693","DOIUrl":null,"url":null,"abstract":"The application of image data is one of the main approaches to creating digital prototypes of inhomogeneous medium elements. The article discusses the method of finite element (FE) analysis based on the use of computed tomography (CT) data of bone organs subjected to external loads. Based on the distribution of the material density in the volume, the geometry of the sample was restored by constructing an FE mesh. The calculations were made on the basis of a three-dimensional isoparametric FE of a continuous medium with a linear approximation of the geometry and displacement field. The data on the medium permeability were taken into account when integrating the local stiffness matrix. The purpose of the study is to describe the general technique for constructing a numerical model that allows static calculation of objects with a porous structure based on their CT data. Kinematic loading was used as boundary conditions. The analysis of the obtained results was carried out by constructing computational and post-processing grids. The qualitative assessment of the simulation results was based on the values of the normalized energy error. In the model problem, a three-point bending of a pig anterior bone sample was considered. The results obtained by numerical calculation were compared with data from a full-scale experiment. The relative error of the results ranged from 3 to 15%. The area of crack formation, determined from a full-scale experiment, was explained by the results of numerical simulation, which showed the occurrence of values exceeding the yield strength for bone material in this area. The obtained estimates reflect not only the effectiveness of the proposed approach, but also the consistency with bending test data. Moreover, the method turns out to be less resource-intensive and more efficient in terms of calculation time relative to existing approaches.","PeriodicalId":401435,"journal":{"name":"2022 VIII International Conference on Information Technology and Nanotechnology (ITNT)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 VIII International Conference on Information Technology and Nanotechnology (ITNT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITNT55410.2022.9848693","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The application of image data is one of the main approaches to creating digital prototypes of inhomogeneous medium elements. The article discusses the method of finite element (FE) analysis based on the use of computed tomography (CT) data of bone organs subjected to external loads. Based on the distribution of the material density in the volume, the geometry of the sample was restored by constructing an FE mesh. The calculations were made on the basis of a three-dimensional isoparametric FE of a continuous medium with a linear approximation of the geometry and displacement field. The data on the medium permeability were taken into account when integrating the local stiffness matrix. The purpose of the study is to describe the general technique for constructing a numerical model that allows static calculation of objects with a porous structure based on their CT data. Kinematic loading was used as boundary conditions. The analysis of the obtained results was carried out by constructing computational and post-processing grids. The qualitative assessment of the simulation results was based on the values of the normalized energy error. In the model problem, a three-point bending of a pig anterior bone sample was considered. The results obtained by numerical calculation were compared with data from a full-scale experiment. The relative error of the results ranged from 3 to 15%. The area of crack formation, determined from a full-scale experiment, was explained by the results of numerical simulation, which showed the occurrence of values exceeding the yield strength for bone material in this area. The obtained estimates reflect not only the effectiveness of the proposed approach, but also the consistency with bending test data. Moreover, the method turns out to be less resource-intensive and more efficient in terms of calculation time relative to existing approaches.
基于ct的骨强度分析数字样机的应用
图像数据的应用是创建非均匀介质元素数字原型的主要方法之一。本文讨论了利用计算机断层扫描(CT)数据进行骨器官外载荷有限元分析的方法。根据材料密度在体积中的分布,通过构建有限元网格恢复样品的几何形状。计算是在连续介质三维等参有限元的基础上进行的,具有几何和位移场的线性近似。在对局部刚度矩阵进行积分时,考虑了介质渗透率数据。本研究的目的是描述构建数值模型的一般技术,该模型允许基于其CT数据对具有多孔结构的物体进行静态计算。以运动载荷为边界条件。通过构建计算网格和后处理网格对得到的结果进行分析。基于归一化能量误差值对仿真结果进行定性评价。在模型问题中,考虑了猪前骨样品的三点弯曲。数值计算结果与全尺寸试验数据进行了比较。结果的相对误差在3% ~ 15%之间。数值模拟的结果解释了从全尺寸实验中确定的裂纹形成区域,该区域出现了超过骨材料屈服强度的值。所得到的估计不仅反映了所提方法的有效性,而且与弯曲试验数据的一致性。此外,与现有方法相比,该方法资源消耗更少,计算时间更短。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书