A four-terminal-pair pulse-driven Josephson impedance bridge for 10 nF:10 nF capacitance ratio measurements

Y. Pimsut, S. Bauer, J. Herick, L. Palafox, O. Kieler, R. Behr
{"title":"A four-terminal-pair pulse-driven Josephson impedance bridge for 10 nF:10 nF capacitance ratio measurements","authors":"Y. Pimsut, S. Bauer, J. Herick, L. Palafox, O. Kieler, R. Behr","doi":"10.1109/CPEM49742.2020.9191785","DOIUrl":null,"url":null,"abstract":"In this paper, the extension of PTB's pulse-driven Josephson impedance bridge to measure four terminal pair impedances is presented. First results for the ratio of two 10 nF capacitance standards will be shown. The difference between the ratio measured by the Josephson impedance bridge at 1233 Hz and the result from an impedance bridge based on inductive voltage dividers is 2 nF/F with a type-A uncertainty of 5 nF/F. Furthermore, the ratio results from this bridge at frequencies from 246 Hz to 4932 Hz are in good agreement with the results from a commercial precision capacitance bridge.","PeriodicalId":373216,"journal":{"name":"2020 Conference on Precision Electromagnetic Measurements (CPEM)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 Conference on Precision Electromagnetic Measurements (CPEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM49742.2020.9191785","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In this paper, the extension of PTB's pulse-driven Josephson impedance bridge to measure four terminal pair impedances is presented. First results for the ratio of two 10 nF capacitance standards will be shown. The difference between the ratio measured by the Josephson impedance bridge at 1233 Hz and the result from an impedance bridge based on inductive voltage dividers is 2 nF/F with a type-A uncertainty of 5 nF/F. Furthermore, the ratio results from this bridge at frequencies from 246 Hz to 4932 Hz are in good agreement with the results from a commercial precision capacitance bridge.
用于10nf: 10nf电容比测量的四端对脉冲驱动约瑟夫森阻抗桥
本文介绍了PTB脉冲驱动约瑟夫森阻抗桥的扩展,以测量四端对阻抗。将显示两个10nf电容标准之比的第一个结果。约瑟夫森阻抗桥在1233hz下测量的比率与基于电感分压器的阻抗桥测量的结果之间的差异为2nf /F, a型不确定度为5nf /F。此外,该电桥在246 Hz至4932 Hz频率范围内的比值结果与商用精密电容电桥的结果很好地吻合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信