Design of CMOS sampling switch for ultra-low power ADCs in biomedical applications

Dai Zhang, Ameya Bhide, A. Alvandpour
{"title":"Design of CMOS sampling switch for ultra-low power ADCs in biomedical applications","authors":"Dai Zhang, Ameya Bhide, A. Alvandpour","doi":"10.1109/NORCHIP.2010.5669444","DOIUrl":null,"url":null,"abstract":"This paper deals with the design of CMOS sampling switch for ultra-low power analog-to-digital converters (ADC) in biomedical applications. General switch design constraints are analyzed, among which the voltage droop due to the subthreshold leakage current constitutes the major error source for low-speed sampling circuits. Based on the analyses, a CMOS sampling switch with leakagereduction has been designed for a 10-bit 1-kS/s successive approximation (SA) ADC in a standard 130 nm CMOS process. Post-layout simulation shows that the ADC with the proposed switch offers an effective number of bits (ENOB) of 9.5 while consuming only 64 nW.","PeriodicalId":292342,"journal":{"name":"NORCHIP 2010","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"NORCHIP 2010","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NORCHIP.2010.5669444","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

Abstract

This paper deals with the design of CMOS sampling switch for ultra-low power analog-to-digital converters (ADC) in biomedical applications. General switch design constraints are analyzed, among which the voltage droop due to the subthreshold leakage current constitutes the major error source for low-speed sampling circuits. Based on the analyses, a CMOS sampling switch with leakagereduction has been designed for a 10-bit 1-kS/s successive approximation (SA) ADC in a standard 130 nm CMOS process. Post-layout simulation shows that the ADC with the proposed switch offers an effective number of bits (ENOB) of 9.5 while consuming only 64 nW.
用于生物医学应用中超低功耗adc的CMOS采样开关设计
本文研究了用于生物医学领域超低功耗模数转换器(ADC)的CMOS采样开关的设计。分析了一般开关设计的约束条件,其中亚阈值泄漏电流引起的电压下降是低速采样电路的主要误差源。在此基础上,设计了一种具有漏出的CMOS采样开关,用于标准130 nm CMOS工艺的10位1-kS/s逐次逼近(SA) ADC。布局后仿真表明,采用该开关的ADC提供9.5的有效位数(ENOB),同时仅消耗64 nW。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信