Rancang Bangun Water Seal Drainage (WSD) Khusus Thorax

Diah Rahayu Ningtias, Bayu Wahyudi, Iqbal Firdaus
{"title":"Rancang Bangun Water Seal Drainage (WSD) Khusus Thorax","authors":"Diah Rahayu Ningtias, Bayu Wahyudi, Iqbal Firdaus","doi":"10.23960/JTAF.V8I2.2563","DOIUrl":null,"url":null,"abstract":"A Water Seal Drainage (WSD) design was made to remove air and fluid from the pleural cavity in the thorax (lung cavity) using a connecting tube or chest tube to maintain the negative pressure of the cavity. Under normal circumstances, the pleural cavity has negative pressure and only a little pleural fluid is filled. Suction pumps have a high pressure with a pressure range of -10 kPa to -80 kPa. The pressure is large enough so that it is not suitable for thorax because it can cause damage to internal organs due to high pressure. WSD specifically for thorax has a low pressure which is below -5 kPa / -40 mmHg. This WSD is equipped with a hand switch, water level and automatic Arduino Uno based exhaust system which has a pressure below -26.6 kPa / -20 cmHg to suction and pressure below -3.4 kPa / -2.6 cmHg to remove liquid from the bottle . The hand switch itself functions as a manual control to make it easier for the user, while the level sensor functions as a safety level for fluid levels in the tool and also an automatic fluid disposal system so that it is more efficient.","PeriodicalId":314761,"journal":{"name":"Jurnal Teori dan Aplikasi Fisika","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Teori dan Aplikasi Fisika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23960/JTAF.V8I2.2563","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A Water Seal Drainage (WSD) design was made to remove air and fluid from the pleural cavity in the thorax (lung cavity) using a connecting tube or chest tube to maintain the negative pressure of the cavity. Under normal circumstances, the pleural cavity has negative pressure and only a little pleural fluid is filled. Suction pumps have a high pressure with a pressure range of -10 kPa to -80 kPa. The pressure is large enough so that it is not suitable for thorax because it can cause damage to internal organs due to high pressure. WSD specifically for thorax has a low pressure which is below -5 kPa / -40 mmHg. This WSD is equipped with a hand switch, water level and automatic Arduino Uno based exhaust system which has a pressure below -26.6 kPa / -20 cmHg to suction and pressure below -3.4 kPa / -2.6 cmHg to remove liquid from the bottle . The hand switch itself functions as a manual control to make it easier for the user, while the level sensor functions as a safety level for fluid levels in the tool and also an automatic fluid disposal system so that it is more efficient.
ranang bangunwater Seal Drainage (WSD)
采用水封引流(WSD)设计,通过连接管或胸管将胸腔内的空气和液体排出,以保持胸腔的负压。正常情况下,胸膜腔呈负压,只有少量胸膜液充盈。吸入泵压力较大,压力范围为- 10kpa ~ - 80kpa。压力太大,不适合胸腔,因为高压会对内脏器官造成损害。专门用于胸部的WSD低压低于-5 kPa / -40 mmHg。该WSD配有手动开关,水位和基于Arduino Uno的自动排气系统,吸气压力低于-26.6 kPa / -20 cmHg,从瓶中取出液体的压力低于-3.4 kPa / -2.6 cmHg。手动开关本身作为手动控制,使用户更方便,而液位传感器作为工具液位的安全水平,也是一个自动流体处理系统,使其更高效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信