Widely tunable difference frequency spectrometer with 200 nm continuously tuning range @ 3.2 up to 3.6 /spl mu/m

M. Laschek, E. Poirot, F. Korte, C. Fallnich, H. Welling
{"title":"Widely tunable difference frequency spectrometer with 200 nm continuously tuning range @ 3.2 up to 3.6 /spl mu/m","authors":"M. Laschek, E. Poirot, F. Korte, C. Fallnich, H. Welling","doi":"10.1109/CLEOE.2000.910254","DOIUrl":null,"url":null,"abstract":"Summary form only given. In trace gas detection on absorption spectroscopy there is a need for widely tunable narrow bandwidth mid infrared light sources. To our knowledge, we report on the first continuously tunable difference frequency generation spectrometer with a mode hop free tuning range of more than 200 nm. The spectrometer consists of a continuously tunable external cavity laser.","PeriodicalId":250878,"journal":{"name":"Conference Digest. 2000 Conference on Lasers and Electro-Optics Europe (Cat. No.00TH8505)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Digest. 2000 Conference on Lasers and Electro-Optics Europe (Cat. No.00TH8505)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CLEOE.2000.910254","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Summary form only given. In trace gas detection on absorption spectroscopy there is a need for widely tunable narrow bandwidth mid infrared light sources. To our knowledge, we report on the first continuously tunable difference frequency generation spectrometer with a mode hop free tuning range of more than 200 nm. The spectrometer consists of a continuously tunable external cavity laser.
宽可调差频光谱仪,200纳米连续调谐范围@ 3.2至3.6 /spl mu/m
只提供摘要形式。在吸收光谱的痕量气体检测中,需要宽可调谐的窄带宽中红外光源。据我们所知,我们报道了第一个连续可调谐的差频产生光谱仪,其模跳无调谐范围超过200 nm。该光谱仪由一个连续可调谐的外腔激光器组成。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信