Measurement of the mid-infrared Fourier spectroscopic imaging of whole human face by portable apparatus (size: 50*50 mm, weight: 200 g)

Photonics Asia Pub Date : 2014-11-20 DOI:10.1117/12.2071422
W. Qi, Yo Suzuki, Masaru Fujiwara, Tsubasa Saito, Satoru Suzuki, P. Abeygunawardhana, Kenji Wada, A. Nishiyama, I. Ishimaru
{"title":"Measurement of the mid-infrared Fourier spectroscopic imaging of whole human face by portable apparatus (size: 50*50 mm, weight: 200 g)","authors":"W. Qi, Yo Suzuki, Masaru Fujiwara, Tsubasa Saito, Satoru Suzuki, P. Abeygunawardhana, Kenji Wada, A. Nishiyama, I. Ishimaru","doi":"10.1117/12.2071422","DOIUrl":null,"url":null,"abstract":"In the daily living space, measurement of the biological-substance distributions such as sebum can be realized by the proposed method of imaging-type 2-dimensional Fourier spectroscopy. This method has the strong robustness for mechanical vibrations. So, the spectrometer (size: 50*50mm, weight: 200g) can be produced without anti-vibration mechanism. Moreover, the phase shifter is a core part of the spectrometer, and it is constructed by the low-price bimorph type actuator which is depending on the vibration control of the piezoceramic in proposed method. It is appropriate as the actuator of the phase shifter from the evaluation results of the actuator straightness and position accuracy in the midinfrared region. As we know, the Fourier spectroscopy has a high light utilization efficiency. Therefore, the low price microbolometer can be used as the imaging sensor. So, the low-price (10,000 U.S. dollars), compact and high portability spectrometer can be produced. Furthermore, the much higher position accuracy in the short wavelength region is requested as we know, the phase shift correction method has been proposed. In this paper, high performance evaluations of the portable spectroscopy apparatus have been discussed by using the CO2 laser spectroscopy results in the midinfrared region. Then, the phase shift correction method was explained. At the end, we demonstrated the feasibility of the mid-infrared imaging of whole human faces without active illuminations.","PeriodicalId":164339,"journal":{"name":"Photonics Asia","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Photonics Asia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2071422","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

In the daily living space, measurement of the biological-substance distributions such as sebum can be realized by the proposed method of imaging-type 2-dimensional Fourier spectroscopy. This method has the strong robustness for mechanical vibrations. So, the spectrometer (size: 50*50mm, weight: 200g) can be produced without anti-vibration mechanism. Moreover, the phase shifter is a core part of the spectrometer, and it is constructed by the low-price bimorph type actuator which is depending on the vibration control of the piezoceramic in proposed method. It is appropriate as the actuator of the phase shifter from the evaluation results of the actuator straightness and position accuracy in the midinfrared region. As we know, the Fourier spectroscopy has a high light utilization efficiency. Therefore, the low price microbolometer can be used as the imaging sensor. So, the low-price (10,000 U.S. dollars), compact and high portability spectrometer can be produced. Furthermore, the much higher position accuracy in the short wavelength region is requested as we know, the phase shift correction method has been proposed. In this paper, high performance evaluations of the portable spectroscopy apparatus have been discussed by using the CO2 laser spectroscopy results in the midinfrared region. Then, the phase shift correction method was explained. At the end, we demonstrated the feasibility of the mid-infrared imaging of whole human faces without active illuminations.
便携式仪器测量全人脸中红外傅立叶光谱成像(尺寸:50*50 mm,重量:200 g)
在日常生活空间中,利用成像型二维傅立叶光谱法可以实现对皮脂等生物物质分布的测量。该方法对机械振动具有较强的鲁棒性。因此,可以生产无防振机构的光谱仪(尺寸:50*50mm,重量:200g)。此外,移相器是光谱仪的核心部件,该移相器由低价格的双晶片型驱动器构成,该驱动器依赖于压电陶瓷的振动控制。从中红外区域的致动器直线度和位置精度评价结果来看,它适合作为移相器的致动器。傅里叶光谱具有很高的光利用效率。因此,低价格的微辐射热计可以用作成像传感器。因此,可以生产出价格低廉(1万美元)、结构紧凑、便携性高的光谱仪。此外,由于在短波长区域对定位精度有更高的要求,提出了相移校正方法。本文利用中红外CO2激光光谱结果,讨论了便携式光谱仪的高性能评价。然后,对相移校正方法进行了说明。最后,我们论证了无主动照明下中红外全人脸成像的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信