{"title":"Disipasi Energi Pada Kolom Dijacketing Dengan Wire Mesh dan Self Compacting Concrete Akibat Beban Siklik","authors":"Hence Michael Wuaten","doi":"10.35139/cantilever.v11i1.136","DOIUrl":null,"url":null,"abstract":"In structures located in earthquake-prone parts, energy dissipation capacity is one of the criteria that must be achieved by the structure. For old structures or built long before earthquake regulations were introduced, it becomes very vulnerable to earthquakes, so it necessitates to be anticipated to prevent collapse, and one method that can be done is by jacketing. In this subject field, testing was conducted using a cyclic load on a reinforced concrete square column measuring 300 mm x 300 mm, which jacketing using wire mesh and self-compacting concrete. From the test results, it was found that in specimens jacketed with M6 wire mesh and self-compacting concrete experienced an increase in accumulative energy dissipation by 23.32% with a relatively minor loss of strength.","PeriodicalId":338977,"journal":{"name":"Cantilever: Jurnal Penelitian dan Kajian Bidang Teknik Sipil","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cantilever: Jurnal Penelitian dan Kajian Bidang Teknik Sipil","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35139/cantilever.v11i1.136","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In structures located in earthquake-prone parts, energy dissipation capacity is one of the criteria that must be achieved by the structure. For old structures or built long before earthquake regulations were introduced, it becomes very vulnerable to earthquakes, so it necessitates to be anticipated to prevent collapse, and one method that can be done is by jacketing. In this subject field, testing was conducted using a cyclic load on a reinforced concrete square column measuring 300 mm x 300 mm, which jacketing using wire mesh and self-compacting concrete. From the test results, it was found that in specimens jacketed with M6 wire mesh and self-compacting concrete experienced an increase in accumulative energy dissipation by 23.32% with a relatively minor loss of strength.
在位于地震易发部位的结构中,消能能力是结构必须达到的指标之一。对于老建筑或者早在地震法规出台之前就建成的建筑,它们在地震前就变得非常脆弱,因此有必要对其进行预估,以防止其倒塌,而一种可以做到的方法是采用护套。在本课题领域中,试验采用循环荷载对尺寸为300 mm x 300 mm的钢筋混凝土方形柱进行了测试,该柱的护套采用钢丝网和自密实混凝土。试验结果表明,采用M6钢丝网和自密实混凝土护套的试件,其累计耗能增加23.32%,强度损失较小。