{"title":"Diagnostic Accuracy of Shear Wave Elastography in Differentiation Between Benign and Malignant Solid Breast Masses Compared with Strain Elastography","authors":"M. Hefeda, Mohammed Abdallah Hablus","doi":"10.11648/J.IJMI.20190702.13","DOIUrl":null,"url":null,"abstract":"The aim of this study was to evaluate the diagnostic performance of shear wave elastography by acoustic radiation force impulse (ARFI) elastography in differentiating malignant and benign breast Lesions in comparison with strain elastography and B mode ultrasound. This was prospective study, we used the commercially available eSie touch elastography imaging. In the shear wave elastography (SWE) we had two modes, the virtual touch imaging (VTI) with interpretation with the 5 points elasticity score and virtual touch quantification (VTQ) technique with the calculation of the Shear wave velocity (SWV). The study included 142 solid breast masses, of them 75 (52.8%) were benign and 67 (47.2%) were malignant. The mean shear wave velocity differed significantly between the benign and malignant groups (2.4+1.3m/sec and 7.3+2.2m/sec respectively, P value <0.0001). the sensitivity, specificity, PPV, NPV and accuracy of strain (eSie touch) elastography score was 83.1%, 88.73%, 88.06%, 84% and 85.92% respectively, which was less than the elastography score by ARFI (92.42%, 92.11%, 91.04%, 93.33% and 92.25% respectively) and less than the VTQ (SWV) which was 94.03%, 95.95%, 95.45% and 95.04% respectively. We concluded that Both the SWE and SE elastography showed significant difference between the benign and malignant masses, and both has added value above B mode ultrasound during routine examination. Shear wave elastography had higher sensitivity and specificity than SE, and less false negative and false positive results. The quantitative SWE (SWV) had the highest diagnostic performance among the different studied techniques.","PeriodicalId":117142,"journal":{"name":"International Journal of Medical Imaging","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Medical Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11648/J.IJMI.20190702.13","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of this study was to evaluate the diagnostic performance of shear wave elastography by acoustic radiation force impulse (ARFI) elastography in differentiating malignant and benign breast Lesions in comparison with strain elastography and B mode ultrasound. This was prospective study, we used the commercially available eSie touch elastography imaging. In the shear wave elastography (SWE) we had two modes, the virtual touch imaging (VTI) with interpretation with the 5 points elasticity score and virtual touch quantification (VTQ) technique with the calculation of the Shear wave velocity (SWV). The study included 142 solid breast masses, of them 75 (52.8%) were benign and 67 (47.2%) were malignant. The mean shear wave velocity differed significantly between the benign and malignant groups (2.4+1.3m/sec and 7.3+2.2m/sec respectively, P value <0.0001). the sensitivity, specificity, PPV, NPV and accuracy of strain (eSie touch) elastography score was 83.1%, 88.73%, 88.06%, 84% and 85.92% respectively, which was less than the elastography score by ARFI (92.42%, 92.11%, 91.04%, 93.33% and 92.25% respectively) and less than the VTQ (SWV) which was 94.03%, 95.95%, 95.45% and 95.04% respectively. We concluded that Both the SWE and SE elastography showed significant difference between the benign and malignant masses, and both has added value above B mode ultrasound during routine examination. Shear wave elastography had higher sensitivity and specificity than SE, and less false negative and false positive results. The quantitative SWE (SWV) had the highest diagnostic performance among the different studied techniques.
横波弹性成像与应变弹性成像鉴别乳腺良恶性实体肿块的诊断准确性比较
本研究的目的是评估剪切波弹性成像的声辐射力脉冲(ARFI)弹性成像在鉴别乳腺恶性和良性病变中的诊断价值,并与应变弹性成像和B型超声进行比较。这是一项前瞻性研究,我们使用了市售的eSie触摸弹性成像。在横波弹性成像(SWE)中,我们有两种模式,即采用5分弹性评分解释的虚拟触摸成像(VTI)和计算横波速度(SWV)的虚拟触摸量化(VTQ)技术。本研究共纳入142例乳腺实性肿块,其中良性75例(52.8%),恶性67例(47.2%)。良性组和恶性组的平均横波速度差异显著(分别为2.4+1.3m/sec和7.3+2.2m/sec, P值<0.0001)。应变(eSie touch)弹性成像评分的灵敏度、特异度、PPV、NPV和准确性分别为83.1%、88.73%、88.06%、84%和85.92%,低于ARFI弹性成像评分(分别为92.42%、92.11%、91.04%、93.33%和92.25%),低于VTQ (SWV)弹性成像评分(分别为94.03%、95.95%、95.45%和95.04%)。我们认为SWE和SE弹性成像在良恶性肿块之间都有显著差异,在常规检查中都比B超有附加价值。横波弹性成像的灵敏度和特异性均高于SE,假阴性和假阳性结果较少。在不同的研究方法中,定量SWE (SWV)的诊断效能最高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信