A NPC step-up inverter for thermo-electric generators

A. Testa, S. D. Caro, T. Scimone, M. Cacciato, G. Scelba
{"title":"A NPC step-up inverter for thermo-electric generators","authors":"A. Testa, S. D. Caro, T. Scimone, M. Cacciato, G. Scelba","doi":"10.1109/ICCEP.2015.7177581","DOIUrl":null,"url":null,"abstract":"Among single stage, single phase, inverter configurations the Neutral Point Clamped topology is advantaged by its quiet rail switching mechanism, producing negligible common mode currents. However, it requires a double input voltage if compared with a classic full bridge inverter. A modified Neutral Point Clamped, three level, single phase, inverter topology is presented in this paper intended for Thermoelectric Generation Systems applications. The proposed topology owns an inner voltage boosting capability, thus, it can be supplied with an input DC voltage equivalent to that of a conventional H bridge inverter, or even lower. Moreover, it is able to compensate voltage drops caused by variations of the thermoelectric generator operating temperature. Finally, no extra high frequency switching devices are introduced to implement the voltage boosting function.","PeriodicalId":423870,"journal":{"name":"2015 International Conference on Clean Electrical Power (ICCEP)","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Clean Electrical Power (ICCEP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCEP.2015.7177581","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Among single stage, single phase, inverter configurations the Neutral Point Clamped topology is advantaged by its quiet rail switching mechanism, producing negligible common mode currents. However, it requires a double input voltage if compared with a classic full bridge inverter. A modified Neutral Point Clamped, three level, single phase, inverter topology is presented in this paper intended for Thermoelectric Generation Systems applications. The proposed topology owns an inner voltage boosting capability, thus, it can be supplied with an input DC voltage equivalent to that of a conventional H bridge inverter, or even lower. Moreover, it is able to compensate voltage drops caused by variations of the thermoelectric generator operating temperature. Finally, no extra high frequency switching devices are introduced to implement the voltage boosting function.
用于热电发电机的NPC升压逆变器
在单级、单相逆变器配置中,中性点箝位拓扑的优势在于其安静轨开关机制,产生的共模电流可以忽略不计。然而,与传统的全桥逆变器相比,它需要双输入电压。本文提出了一种改进的中性点箝位,三电平,单相逆变器拓扑,用于热电发电系统的应用。所提出的拓扑结构具有内部升压能力,因此,它可以提供相当于传统H桥逆变器的输入直流电压,甚至更低。此外,它还能补偿由于热电发电机工作温度变化而引起的电压降。最后,没有引入额外的高频开关器件来实现升压功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信