Costs and Unreliability Minimization of Transmission System Shield Wires

T. N. Kannan, J. Davey, P. Rastgoufard, J. Bian
{"title":"Costs and Unreliability Minimization of Transmission System Shield Wires","authors":"T. N. Kannan, J. Davey, P. Rastgoufard, J. Bian","doi":"10.1109/SSST.1992.712265","DOIUrl":null,"url":null,"abstract":"The purpose of this investigation is to improve the efficiency of the transmission lines by minimizing the current flowing through the shield wires which are utilized along the phase wires to protect them from lightning. The result of this investigation is presented by computation of currents coupled into the shield wires from balanced current flows in parallel three phase circuits and a computation of current flow in the shield wires during short circuit condition when the shield wires become a part of the ground return circuit. A computer package that evaluates the shield wire current for balanced three phase circuits is developed. Results for a specific vertically configured transmission system art presented in this paper.","PeriodicalId":359363,"journal":{"name":"The 24th Southeastern Symposium on and The 3rd Annual Symposium on Communications, Signal Processing Expert Systems, and ASIC VLSI Design System Theory","volume":"150 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The 24th Southeastern Symposium on and The 3rd Annual Symposium on Communications, Signal Processing Expert Systems, and ASIC VLSI Design System Theory","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SSST.1992.712265","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The purpose of this investigation is to improve the efficiency of the transmission lines by minimizing the current flowing through the shield wires which are utilized along the phase wires to protect them from lightning. The result of this investigation is presented by computation of currents coupled into the shield wires from balanced current flows in parallel three phase circuits and a computation of current flow in the shield wires during short circuit condition when the shield wires become a part of the ground return circuit. A computer package that evaluates the shield wire current for balanced three phase circuits is developed. Results for a specific vertically configured transmission system art presented in this paper.
输电系统屏蔽线的成本和不可靠性最小化
本研究的目的是通过最大限度地减少流过屏蔽线的电流来提高传输线的效率,屏蔽线沿着相线被用来保护它们免受雷击。通过计算并联三相电路中平衡电流耦合到屏蔽线上的电流,以及当屏蔽线成为接地回路的一部分时短路情况下屏蔽线内的电流,给出了研究结果。开发了一种计算平衡三相电路屏蔽线电流的计算机程序包。本文给出了一个具体的垂直配置的传动系统的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信