Measurement of Partial Discharge in Air Insulation by using UHF Double Layer Bowtie Antenna with Modified Wings Edges

J. P. Uwiringiyimana, U. Khayam
{"title":"Measurement of Partial Discharge in Air Insulation by using UHF Double Layer Bowtie Antenna with Modified Wings Edges","authors":"J. P. Uwiringiyimana, U. Khayam","doi":"10.1109/ICEEI47359.2019.8988866","DOIUrl":null,"url":null,"abstract":"The measurement of partial discharge (PD) by detecting the released energy from the PD source in the form of electromagnetic wave during the corona discharge(discharge in air) by using Ultra-High Frequency (UHF) antenna has been an accurate diagnostic technique to determine the condition and quality of the insulation system in high voltage equipements. The UHF sensors have shown a great advantage in the detection of partial discharge because they are capable to detect partial discharge signal online without the need of prior shutdown of the high voltage apparatus. This paper discuss the measurement of partial discharge in air insulation by using the designed UHF double layer bowtie antenna with modified antenna wings edges. The double layer bowtie antenna was used to detect PD based on EM waves induced by PD in air insulation. The PD measurement results obtained by using the designed double layer bowtie were compared with PD measurements results obtained by using the RC detector which was taken as a comparison sensor. The characteristics of PD induced EM waves measured by RC detector and double layer bowtie have been investigated. The PD measurement was performed at three applied voltage levels namely, 5 kV, 6 kV and 7kV. The PD measurement results have shown that the higher applied voltage, the high Vpp magnitude for PD waveform, PD charge magnitude and PD number in both negative and positive half cycle.","PeriodicalId":236517,"journal":{"name":"2019 International Conference on Electrical Engineering and Informatics (ICEEI)","volume":"83 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Electrical Engineering and Informatics (ICEEI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEEI47359.2019.8988866","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

The measurement of partial discharge (PD) by detecting the released energy from the PD source in the form of electromagnetic wave during the corona discharge(discharge in air) by using Ultra-High Frequency (UHF) antenna has been an accurate diagnostic technique to determine the condition and quality of the insulation system in high voltage equipements. The UHF sensors have shown a great advantage in the detection of partial discharge because they are capable to detect partial discharge signal online without the need of prior shutdown of the high voltage apparatus. This paper discuss the measurement of partial discharge in air insulation by using the designed UHF double layer bowtie antenna with modified antenna wings edges. The double layer bowtie antenna was used to detect PD based on EM waves induced by PD in air insulation. The PD measurement results obtained by using the designed double layer bowtie were compared with PD measurements results obtained by using the RC detector which was taken as a comparison sensor. The characteristics of PD induced EM waves measured by RC detector and double layer bowtie have been investigated. The PD measurement was performed at three applied voltage levels namely, 5 kV, 6 kV and 7kV. The PD measurement results have shown that the higher applied voltage, the high Vpp magnitude for PD waveform, PD charge magnitude and PD number in both negative and positive half cycle.
利用改进翼缘的超高频双层蝴蝶结天线测量空气绝缘局部放电
利用超高频(UHF)天线探测局部放电源在电晕放电(空气放电)过程中以电磁波形式释放的能量来测量局部放电(PD),已成为确定高压设备绝缘系统状态和质量的一种准确诊断技术。超高频传感器在局部放电检测中显示出很大的优势,因为它能够在线检测局部放电信号,而不需要事先关闭高压设备。本文讨论了利用设计的改进天线翼边的超高频双层领结天线对空气绝缘局部放电的测量。采用双层领结天线对空气绝缘中放电产生的电磁波进行检测。将设计的双层领结测得的局部放电测量结果与RC探测器测得的局部放电测量结果进行了比较。研究了用RC探测器和双层领结测量PD感应电磁波的特性。PD测量在三个施加电压水平下进行,即5kv, 6kv和7kV。PD测量结果表明,施加电压越高,PD波形的Vpp值、PD电荷值和PD数在负半周和正半周内都越高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信