{"title":"Tapping existing LCC-HVdc systems with Voltage Source Converters","authors":"D. Suriyaarachchi, C. Karawita, M. Mohaddes","doi":"10.1109/PESGM.2016.7741731","DOIUrl":null,"url":null,"abstract":"This paper presents the application of a Full-bridge modular multi-level converter (FB-MMC) to tap an existing LCC-HVdc system. During faults, the dc voltage of the FB-MMC is controlled to reduce the fault current instead of blocking the converters. Electromagnetic Transient Simulations performed with PSCAD has been used to demonstrate the performance of the proposed system. Control strategies have been proposed in case of ac and dc faults at the three terminals. The results presented in this paper clearly indicate the benefits of using a FB-MMC with a controlled fault clearing strategy to tap an existing LCC-HVdc system.","PeriodicalId":155315,"journal":{"name":"2016 IEEE Power and Energy Society General Meeting (PESGM)","volume":"130 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Power and Energy Society General Meeting (PESGM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESGM.2016.7741731","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

This paper presents the application of a Full-bridge modular multi-level converter (FB-MMC) to tap an existing LCC-HVdc system. During faults, the dc voltage of the FB-MMC is controlled to reduce the fault current instead of blocking the converters. Electromagnetic Transient Simulations performed with PSCAD has been used to demonstrate the performance of the proposed system. Control strategies have been proposed in case of ac and dc faults at the three terminals. The results presented in this paper clearly indicate the benefits of using a FB-MMC with a controlled fault clearing strategy to tap an existing LCC-HVdc system.
利用电压源转换器开发现有的lc - hvdc系统
本文介绍了一种全桥模块化多电平变换器(FB-MMC)在现有lc - hvdc系统中的应用。在故障期间,控制FB-MMC的直流电压以减小故障电流,而不是阻塞变换器。利用PSCAD进行的电磁瞬变仿真验证了所提出系统的性能。提出了三端交直流故障时的控制策略。本文提出的结果清楚地表明,使用FB-MMC与受控故障清除策略来利用现有的lc - hvdc系统的好处。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信